64
GB
GB
6. INSTALLATION OF THE INDOOR UNIT
N
L 4(SI) 2(N) 1(L)
3
4(SI)
2(N) 1(L)
OUTDOOR UNIT
Signal
N
L
Stand By
INDOOR UNIT
Single unit connection
N
L 4(SI) 2(N) 1(L) O(L)
3
4(SI)
2(N) 1(L) O(L)
OUTDOOR UNIT
Signal
N
L
Stand By
INDOOR UNIT
Wall monosplit unit connection
6.5 Electrical connections between the units
Power
supply
Power
supply
Pipes and cables positioning
The connection cables and the condensate plain pipe must be fixed toge-
ther to the refrigerant pipes, using protective tape
a
Aluminized tape
b
Refrigeration piping
Indoor unit condensation drain
Electrical connection cable
between the units
- Provide to use a protection sheet for the cables exposed to the outside.
- It is recommended to set the cables with a drip-proof run in order to
avoid possible infiltrations of water in the outdoor unit.
- Combine the electrical connection cable of the two units to the refrige-
ration piping and wrap with reinforced tape, possibly alluminized.
- If the cable cannot be solid with the piping, make a suitable wall ancho-
rage by means of a cable fastener or hose clips.