Derivative (Derivative Parameter)(Default =250):
This parameter is can be adjusted from 0 to 3600 value.
Period Time (second)(Default =1):
This parameter is can be adjusted from 1 to 50 seconds value.
Auto Tune:(Default =OFF):
This parameter value must be 'ON' for starting the auto tune function. After auto
tune function is finished, automatically this parameter value is return to 'OFF' value.
6.1.3. HUMIDITY PARAMETERS
Min. Set (%)(Default =0):
Humidity set value can not be lower than this value. This parameter value can be
adjusted from minimum value of device scale to Max. Set value parameter
Max. Set (%)(Default =100):
Humidity set value can not be greater than this value. This parameter value
can be adjusted from Min. Set value parameter to maximum value of the device scale.
Offset(%)(Default =0):
Humidity sensor offset value is can be set with this parameter.
This parameter is can be adjusted from -10 to 10 %RH.
Hysteresis (%)(Default =1):
Hysteresis value can be adjusted wit this parameter.
This parameter is can be adjusted from 1 to 10 %RH.
Scale (Default =Scale2)
This parameter is active only if analogue inputs type is selected as a universal
(EGG HATCHER X/20.X.X.X). Parameter value is can be adjusted as a
S
cale1: 0-20mA,
Scale2: 4-20mA
ENG EGG HATCHER 02 V01 04/16