6.1.2. TEMPERATURE PARAMETERS
Unit Select(Default =°C):
Device temperature unit is can be
selected as a '°C' or '°F' with this parameter.
Heat Min. Set (°C):(Default =10)
Heating Temperature set value can not be lower than this value. This
parameter value can be adjusted from minimum value of device scale to Heating Max. Set parameter value.
Heat Max. Set (°C):(Default =40)
Heating Temperature set value can not be higher than this value. This
parameter value can be adjusted from Heating Min Set parameter value to maximum value of device scale.
Cool Min. Set (°C):(Default =10)
Cooling Temperature set value can not be lower than this value. This
parameter value can be adjusted from minimum value of device scale to Cooling Max. Set parameter value.
Cool Max. Set (°C):(Default =40)
Cooling Temperature set value can not be higher than this value. This
parameter value can be adjusted from Cooling Min Set parameter value to maximum value of device scale.
Sensor Offset(°C):(Default =0)
This parameter is can be adjusted from -10.0°C to 10.0°C
Heat Hysteresis:(Default =0.1°C)
This parameter is active If heating control selection parameter value is
selected as a ON/OFF. This parameter value is can be adjusted
0.1°C to 10.0 °C for Pronem Mini PMI-P ( -20.0°C, 80.0°C )
0.1°C to 18.0 °C for Pronem Mini PMI-P ( -4.0°C, 176.0°C )
Cool Hysteresis:(Default =0.1°C)
This parameter value is can be adjusted
0.1°C to 10.0 °C for Pronem Mini PMI-P ( -20.0°C, 80.0°C )
0.1°C to 18.0 °C for Pronem Mini PMI-P ( -4.0°C, 176.0°C )
Sens Low Value (Default =-20.0)
This parameter is can be adjusted from -200.0°C to 1000.0°C
Sens High Value (Default =80.0)
This parameter is can be adjusted from -200.0°C to 1000.0°C
Sensor Scale (Default =Scale1)
Scale1: 0-20mA,
Scale2: 4-20mA
The below parameters is can be used If temperature control selection parameter is selected as a 'PID'.
Proportionally (Proportional Control Parameter)(Default =50):
This parameter is can be adjusted form 0 to
100 value.
Integral(Integral Parameter)(Default =1000):
This parameter is can be adjusted from 0 to 3600 value.
ENG EGG HATCHER 02 V01 04/16