EMKO EGG HATCHER User Manual Download Page 1

EGG HATCHER

 

HATCHING CONTROL DEVICE

USER MANUAL

EMKO ELEKTRONİK A.Ş.

Demirtaş Org. San. Blog.
Karanfil Sk. No:6 TR

16369 Bursa / TURKEY

Telefon:0224 261 1990
Faks:

0224 261 1912

Web Sitesi:

www.emkoelektronik.com.tr

email:

[email protected]

User Manual  ENG EGG HATCHER 02 V01 04/16

Summary of Contents for EGG HATCHER

Page 1: ...MANUAL EMKO ELEKTRON K A Demirta Org San Blog Karanfil Sk No 6 TR 16369 Bursa TURKEY Telefon 0224 261 1990 Faks 0224 261 1912 Web Sitesi www emkoelektronik com tr email exposales emkoelektronik com tr...

Page 2: ...13 3 4 Button Definetions 14 4 SHUTTER CONTROL 15 5 SETTINGS 16 6 ADVANCED SETTINGS 17 6 1 Control Parametres 18 6 1 1 General Parameters 6 1 2 Temperature Parameters 6 1 3 Humidity Parameters 6 1 4 T...

Page 3: ...11 SPECIFICATIONS 35 12 OTHER INFORMATIONS 36 1 INTRODUCTION 1 1 General Specifications ENG EGG HATCHER 02 V01 04 16 3...

Page 4: ...noise lightning humidity temperature etc although EGG HATCHER device is designed manufactured and tested according to related standards Emko Elektronik is not responsible for losses that occurs with...

Page 5: ...ing is completed so that electric shock and trouble with the unit can be prevented Never attempt to disassemble modify or repair this unit Tampering with the unit may results in malfunction electric s...

Page 6: ...2 1 General Description 2 2 Front View Dimensions and Panel Cutout of EGG HATCHER ENG EGG HATCHER 02 V01 04 16 6...

Page 7: ...ENG EGG HATCHER 02 V01 04 16 7...

Page 8: ...on parts are not properly tightened These precautions for the safety of the person who does the panel mounting The unit is designed for panel mounting 1 Insert the unit in the panel cut out from the f...

Page 9: ...2 4 Electrical Wiring Diagram Electrical Wiring Diagram for Pronem Type Input Card ENG EGG HATCHER 02 V01 04 16 9...

Page 10: ...Electrical Wiring Diagram for mA Type Input Card ENG EGG HATCHER 02 V01 04 16 10...

Page 11: ...rature Cabinet Humidty Hatching time is showed as a day hours and minute in label which is bottom of temperature and humidity label When any alarm is occurs the alarm definetion is showed in this labe...

Page 12: ...Outputs 0 Cooling SSR output status 1 Heating SSR output status 2 Tray Rotation Left Relay output satus 3 Tray Rotation Right Relay output satus 4 Shutter Close Relay output status 5 Shutter Open Rel...

Page 13: ...Used to start manual Tray rotation 3 3 Menus Shutter Control Settings Advanced Settings Logs Alarms Language Selection ENG EGG HATCHER 02 V01 04 16 13...

Page 14: ...d to increase decrease parameter s value Left Right buttons Used to go left or right in menus Confirm button Used to go in to selected page to make parameter s cell available to change and to confirm...

Page 15: ...L SHUTTER CONTROL Shutter control manual automatic selection is can be made in this page If shutter control is selection as a manual shutter status is can be adjusted manualy ENG EGG HATCHER 02 V01 04...

Page 16: ...This parameter is can be adjusted from 1 to 100 When this parameter value is 1 if decrement button is pressed OFF is observed In this time the screen turns off Backlight OffTime sec Default 20 Time fo...

Page 17: ...6 ADVANCED SETTINGS These following pages can be accessed via Advanced Settings Menu 6 1 Control Parameters 6 2 Device Settings 6 3 Calibration ENG EGG HATCHER 02 V01 04 16 17...

Page 18: ...output function selection can be made with this parameter This parameter must be set SU PSK for Water spray function or ALARM for Humidity Alarm function Buzzer Function Select Default OFF Buzzer act...

Page 19: ...ssive Rotation Motor Feedback Default OFF Whether tray motor limit switch using can be made with this parameter If tray motor limit switch will be use this parameter value must be ON otherwise paramet...

Page 20: ...ce scale Sensor Offset C Default 0 This parameter is can be adjusted from 10 0 C to 10 0 C Heat Hysteresis Default 0 1 C This parameter is active If heating control selection parameter value is select...

Page 21: ...minimum value of device scale to Max Set value parameter Max Set Default 100 Humidity set value can not be greater than this value This parameter value can be adjusted from Min Set value parameter to...

Page 22: ...o temperature alarm set maximum parameter value Min Set C Default 20 Temperature alarm set value can not be lower than this value This parameter value can be adjusted from minimum value of device scal...

Page 23: ...an be adjusted from minimum value of device scale to temperature alarm set maximum parameter value Min Set C Default 20 Humidity alarm set value can not be lower than this value This parameter value c...

Page 24: ...press to ENTER button second value is can be adjusted with increment and decrement button after third press to ENTER button parameter value is saved Output Period hour min Default 0 Relay2 Output peri...

Page 25: ...Control Output Selection parameter is selected as a ANL Scale1 0 20mA 0 10Vdc Scale2 4 20mA 2 10Vdc Travel Time sec Default 5 This parameter defines after how many seconds shutter is completely opened...

Page 26: ...ed with increment and decrement button after third press to ENTER button parameter value is saved Output Period hour min Default 0 Tray rotation Output period time value is adjusted with this paramete...

Page 27: ...g Day value is adjusted with this parameter This parameter value is can beadjusted from 2 to 0 day Period day Default 1 Hatching period time is adjusted via this parameter This parameter value is can...

Page 28: ...6 2 DEVICE SETTINGS 6 2 1 Date Time Settings When you return back to previous page settings are registered ENG EGG HATCHER 02 V01 04 16 28...

Page 29: ...vice by making power off and on To update HMI s bitmaps 1 Insert the flash drive that contains EGGBMP_Vxx txt file into the USB port 2 Restart the HMI device by making power off and on Note Formatting...

Page 30: ...6 2 3 Default Settings This section is used to return default settings back 6 2 4 Change Password This section is to change Technician Password ENG EGG HATCHER 02 V01 04 16 30...

Page 31: ...ty Range Humidity Events occurs when related digital input becomes active Lid Open Rotation Motor Fault Fan Fault Events occurs related Process control Incubation Period Finish Events occurs when sens...

Page 32: ...y Alarms occurs when related digital input becomes active Lid Open Rotation Motor Fault Fan Fault Alarm occurs related Process control Incubation Period Finish Alarm occurs when sensors became broken...

Page 33: ...9 LANGUAGE SELECTION ENG EGG HATCHER 02 V01 04 16 33...

Page 34: ...Alarm Output Process Value Alarm Output ALARM SET HYS ALARM SET HYS ON OFF Alarm Output Process Value Band Alarm SET SET ALARM SET SET ALARM SET HYS HYS SET HYS ProcessSet value HysteresisvalueforAlar...

Page 35: ...lution Operating Conditions Continuous Device Supply Voltage and Power 100 240 V V 15 10 50 60 Hz 7VA 24 V V 15 10 50 60 Hz 7VA 24 V Z 15 10 7W Analogue Sensor Inputs 0 20mA Z PT 100 IEC751 ITS90 PRON...

Page 36: ...Sanayi B lgesi Karanfil Sk No 6 16369 BURSA TURKEY Tel 224 261 1900 Fax 224 261 1912 Repair and Maintenance Service Information Emko Elektronik Sanayi ve Ticaret A Demirta Organize Sanayi B lgesi Kar...