Relay Terminal
The SmartLog Pro™ features a relay terminal that can
be integrated with electronic door locks, lights, buzzers,
etc.
Contact Rating
1A @ 30VDC, .5A @
125VAC
Maximum Switching Power 30W
Maximum Switching Voltage 250VAC, 220VDC
Maximum Switching Current 1A
7. Tap the Network button to access the Wired
Newtork Setup Menu. This menu will allow you to
view and edit any network settings if desired.
Figure 10. Locating the IP address in the Admin Menu
The relay open and close (activation) time may be
modified using the TEAM5 Software. See the
TEAM5
User Manual
for more information.
Network Setup
The following procedures will outline how to connect
your SmartLog Pro™ to a local area network (LAN)
using its embedded Ethernet communication module.
DYNAMIC IP PROCEDURE
1. Verify that the Ethernet cable is securely connected
to your network and SmartLog Pro™. The LEDs on
the Ethernet port will illuminate when a connection
to the network is established.
2. The SmartLog Pro™ will automatically obtain an
IP address from the DHCP server. The IP address
can be located within the Admin Menu.
3. To access the Admin Menu, tap 0 then Enter on the
touchscreen keypad.
4. The SmartLog will prompt for the Admin ID. Tap 0
then Enter.
5. The SmartLog will prompt for the Admin PIN. Tap 0
then Enter.
6. The Admin Menu will appear. The IP address
can be found in the top left corner. Take note
of this address as it will be required to establish
communication between the SmartLog Pro and the
TEAM5 Server Software.
Normally Closed
Common
Normally Open
Figure 9. Relay terminal contacts located on the back of
the SmartLog Pro™
Figure 11. Locating the Newtork button in the Admin
Menu
Figure 12. Wired Network Setup menu