4.Function Parameter List
EM8 User's Manual
29
Code
Name
Description
Min.
unit
Factory
setting
Change
Code
addr.
C-34
Step 7 running
direction
0: FWD
1: REV
1
0
7EH
C-35
Step 7 Acc/Dec time
0.1~6000s
0.1
10.0
7FH
C-36
Jump frequency 1
0.00~Upper-limit frequency
0.01
0.00
80H
C-37
Amplitude of jump
frequency 1
0.00 ~5.00Hz
0.01
0.00
81H
C-38
Jump frequency 2
0.00~Upper-limit frequency
0.01
0.00
82H
C-39
Amplitude of jump
frequency 2
0.0 0~5.00Hz
0.01
0.00
83H
C-40
Jump frequency 3
0.00~Upper-limit frequency
0.01
0.00
84H
C-41
Amplitude of jump
frequency 3
0.00 ~5.00Hz
0.01
0.00
85H
C-42
Acceleration time 2
0.1~ 6000s
0.1
*
86H
C-43
Deceleration time 2
0.1~ 6000s
0.1
*
87H
C-44
Acceleration time 3
0.1~ 6000s
0.1
*
88H
C-45
Deceleration time 3
0.1~ 6000s
0.1
*
89H
C-46
Acceleration time 4
0.1~ 6000s
0.1
*
8AH
C-47
Deceleration time 4
0.1~ 6000s
0.1
*
8BH
C-48
Built-in PID control
0: No PID control
1: Normal PID control
2: Constant-pressure
water-supply PID
3: Double-pump constant
pressure water-supply PID
(Need accessory)
4: Triple-pump constant pressure
water-supply PID (Need
accessory)
5: Four-pump constant pressure
water-supply (Need
accessories)
1
0
×
8CH
C-49
Built-in PID
configuration
channel selection
0: Panel potentiometer
1: Panel digital setting
2: External voltage signal 1
(0~10V)
3: External voltage signal 2
(-10V~10V)
4: External current signal
5: External pulse signal
6: RS485 interface setting
1
0
×
8DH