3.Operation and Running
EM8 User's Manual
19
3.6.2Monitor parameter inquiry
Running
Description
Display
For example:
looking over the
setting frequency
Current state of running panel
monitor parameter inquiry mode.
d-0 (Example)
Monitor code plus 1
d-1
Modify monitor code to the
parameter d-4 which needs inquiry.
d-4
Confirm the inquiry monitor item.
Display the Parameter value according
to d-4 to set the frequency.
Switch the working mode of
running panel according to needs.
3.6.3 Setting parameter
Running
Description
Display
Change Acc time 1
from 5.0s to 10.0s (For
example)
Current state of running panel:
parameter setting mode (Basic
parameter for example).
A-0
Modify the code of parameter to
the expected value: A-7.
For example: A-7 (Acc time 1)
Confirm the parameter item being
modified.
Display the parameter value of A-7: 5.0
Modify the parameter to the
expected value: 10.0.
10.0
Confirm the parameter value, and
store them into the internal store
memory.
A-7
Switch the working mode of
running panel according to needs.
3.6.4 Modification of digital setting frequency
Mode 1
:
Running
Description
Display
Change the current
digital setting frequency
Current state of running panel:
state monitor mode.
Running parameter (Decided by
parameter b-71)
Change digital setting frequency
to the expected value.
Digital setting frequency.
Store the digital setting frequency
into the internal, and return the
state monitor mode.
Running parameter (Decided by
parameter b-71)
The digital setting frequency after
modification is not stored into the
internal memory, the inverter will
return the state monitor mode
after power-off.