background image

49P11-843

Emerson SureSwitch™

N° DE PIEZA 

37-7295B

Reemplaza 37-7295A

1304

INSTRUCCIONES DE INSTALACIÓN 

EL NO LEER Y SEGUIR CON CUIDADO TODAS LAS INSTRUCCIONES ANTES DE 
INSTALAR O UTILIZAR ESTE CONTROL PODRÍA CAUSAR LESIONES PERSONALES 
Y/O DAÑOS MATERIALES.

 

 PRECAUCIONES

CONTENIDO

Descripción .......................................................................

1

Precauciones ....................................................................

1

Especificaciones

 ................................................................

2

Montaje ............................................................................

2

Referencia rápida ................................................................. 2

Funcionamiento ................................................................

3

Solución de problemas ......................................................

3

Diagramas de conexiones eléctricas .................................... 4

 

 DESCRIPCIÓN

SureSwitch™ es un relé de control electrónico que puede utilizarse 

para reemplazar contactores monopolares y bipolares comúnmente 

utilizados en aires acondicionados, bombas de calor y otras aplicaciones. 

Un algoritmo de conmutación patentado reduce la formación de arcos 

entre contactos, lo que prácticamente elimina el picado y la soldadura 

y prolonga la vida útil. El mecanismo de conmutación está sellado para 

impedir el ingreso de insectos y residuos.   
SureSwitch también incluye características avanzadas para la solución 

de problemas de calefacción, ventilación y aire acondicionado y para 

una mayor confiabilidad del sistema:
•  Protección contra caídas de voltaje de línea

•  Protección de ciclos cortos

•  Retardo de inicio aleatorio

•   Recuento de ciclo de vida útil

SureSwitch es similar a un contactor de 

1

 

1

/

2

 polos ya que solo se 

conmuta la terminal del compresor 

C

. La terminal del compresor 

R

 se 

conecta mediante una barra de cortocircuito a la entrada de línea 

L

1

y se energiza incluso cuando no hay presente una llamada.

La instalación debe ser realizada por un técnico especializado en 

calefacción y aire acondicionado o por un electricista profesional.

No exceda los valores nominales especificados.

Todas las conexiones eléctricas deben cumplir con los códigos y 

reglamentaciones locales y nacionales.
Este control es un instrumento de precisión y debe manipularse 

con cuidado. La manipulación descuidada o la distorsión de 

los componentes podrían hacer que el control no funcionara 

correctamente.

Una vez finalizada la instalación o el reemplazo, siga las instrucciones 

de instalación y mantenimiento recomendadas por el fabricante para 

asegurar el funcionamiento adecuado de la unidad.
SureSwitch no contiene piezas que puedan ser reparadas por el 

usuario. Debe reemplazarse la unidad completa. 

www.white-rodgers.com

www.emersonclimate.com

Operador: ¡Guarde estas instrucciones para uso futuro!

Si no se tienen en cuenta las siguientes advertencias, podrían 
producirse lesiones personales o daños materiales.

RIESGO DE INCENDIO

•  No exceda el voltaje especificado.

•  Reemplace el control actual por otro del mismo 

modelo y número.

•  Proteja el control contra el contacto directo con el 

agua (goteo, rociado, lluvia, etc.).

•  Si el control ha estado en contacto directo con agua, 

cámbielo por otro.

•  Identifique todos los cables antes de desconectarlos 

cuando realice el mantenimiento de los controles. 

Un error en las conexiones puede hacer que la unidad 

funcione de forma incorrecta y peligrosa.

•  Proteja y pase los cables por un lugar seguro después 

de su instalación.

RIESGO DE CHOQUE ELÉCTRICO

•  Desconecte la alimentación eléctrica antes de realizar 

el mantenimiento de la unidad.

•  Asegúrese de que la unidad está debidamente 

conectada a tierra.

•  Asegúrese de que el cable neutro y vivo de la línea 

están debidamente conectados.

•  La salida del compresor "R" no se conmuta y está 

energizada en todo momento.

Summary of Contents for White Rogers SureSwitch 49P11-843

Page 1: ...on should be done by a qualified heating and air conditioning contractor or licensed electrician Do not exceed the specification ratings All wiring must conform to local and national electrical codes and ordinances This control is a precision instrument and should be handled carefully Rough handling or distorting components could cause the control to malfunction Following installation or replaceme...

Page 2: ...ng plate has four mounting holes that match the typical mounting screw locations of a single or two pole contactor Secure the bottom mounting plate to the control box using the two self tapping screws provided 6 Replace the main housing on the mounting plate and secure by tightening all four housing captive screws Take care to avoid over tightening 7 Connect line and control voltage wiring Refer t...

Page 3: ...e disabled by setting the Delay dipswitch to the OFF position LINE VOLTAGE BROWNOUT PROTECTION Brownout protection will de energize the compressor and fan if line voltage drops below 180 VAC for more than four seconds during a call for compressor operation Compressor operation will not resume until line voltage returns to a minimum of 190VAC In addition SureSwitch will not attempt to start the com...

Page 4: ...rankcase Heater 2Wire Hardstart Kit optional FAN HERM COM Line voltage Low voltage Line voltage optional circuit Optional components Legend T1 Fan Run T2 Start Separate Capacitor Optional Fan Capacitor Fan Run Common Start Fan Separate Capacitor Optional Capacitor 49P11 843 SureSwitch 4 Wire Condenser Fans 3 Wire Condenser Fans The following wiring diagram is meant to represent typical installatio...

Page 5: ...on ou par un électricien agréé N excédez pas les spécifications du produit Tout le câblage doit respecter les codes et règlements locaux et nationaux de l électricité Ce thermostat est un instrument de précision et il doit être manipulé avec soin Une manipulation robuste ou la modification des composantes peuvent causer la défaillance du thermostat Après l installation ou le remplacement respectez...

Page 6: ...laque de montage du boîtier principal 5 Le bas de la plaque de montage est pourvu de quatre trous de montage qui correspondent à l emplacement typique des vis de montage pour un contacteur mono ou bipolaire Fixer le bas de la plaque de montage sur la boîte des commandes à l aide des deux vis autotaraudeuses fournies 6 Replacer le boîtier principal sur la plaque de montage et fixer le tout en serra...

Page 7: ...baisse de tension coupe le compresseur et le ventilateur lorsque la tension de ligne chute sous 180V c a pendant plus de quatre secondes alors que le système appelle au fonctionnement du compresseur Le compresseur ne redémarre pas tant que la tension n atteint pas au minimum 190V c a De plus le module SureSwitch ne tente pas de redémarrer le compresseur tant que la tension de ligne est inférieure ...

Page 8: ...cultatives Légende T1 Ventilateur Marche T2 Démarrage Condensateur du ventilateur Ventilateur Marche Neutre Démarrage Condensateur distinct facultatif 49P11 843 SureSwitch Ven lateurs de condensateur à 4 fils Ven lateurs de condensateur à 3 fils Condensateur du ventilateur Condensateur distinct facultatif Condensateur du ventilateur Condensateur distinct facultatif Condensateur du ventilateur Cond...

Page 9: ...cionado o por un electricista profesional No exceda los valores nominales especificados Todas las conexiones eléctricas deben cumplir con los códigos y reglamentaciones locales y nacionales Este control es un instrumento de precisión y debe manipularse con cuidado La manipulación descuidada o la distorsión de los componentes podrían hacer que el control no funcionara correctamente Una vez finaliza...

Page 10: ...taje tiene cuatro orificios de montaje que coinciden con las ubicaciones típicas de los tornillos de montaje de un contactor monopolar o bipolar Fije la placa de montaje inferior a la caja de control utilizando los dos tornillos autorroscantes suministrados 6 Vuelva a colocar la carcasa principal sobre la placa de montaje y fíjela ajustando los cuatro tornillos cautivos de la carcasa Evite ajustar...

Page 11: ...ONTRA CAÍDA DEVOLTAJE DE LÍNEA La protección contra caídas de voltaje desenergiza el compresor y el ventilador si el voltaje de línea cae por debajo de los 180VCA durante más de cuatro segundos durante una llamada de funcionamiento de compresor El funcionamiento del compresor no se reanudará hasta que el voltaje de línea vuelva a 190VCA como mínimo Además SureSwitch no intentará iniciar el compres...

Page 12: ...ERM COM Voltaje de línea Bajo voltaje Circuito opcional de voltaje de línea Componentes opcionales Leyenda T1 Ventilador T2 Arranque Capacitor del ventilador Ventilador Común Arranque Capacitor separado opcional 49P11 843 SureSwitch Ven ladores de condensador de 4 cables Ven ladores de condensador de 3 cables Capacitor del ventilador Funcio namiento Capacitor separado opcional Funcio namiento El s...

Reviews: