background image

© 2017 United Technologies Corporation                                             1 / 2                                                       466-5273 

• REV C • ISS 14FEB17 

 

UltraSync  Modular Hub

 

Relay Expansion Module 
Installation Sheet

 

 

UM-R4 
UM-R10 

 

 English Installation Sheet 

 

Product Summary:       

These modules add 4 or 10 relay outputs to an UltraSync Modular Hub system.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

 

 

 

 

Installation 

1.  Pull down the din rail tab on the bottom of the module. 

 

 

 

 

 

 

 

 

 

 

2.  Hang the module on the top of the din rail, tilting the 

bottom of the module outward. Once the module is 
vertical, lock the module on the rail by pushing the tab up. 

 
 
 
 

 
 
 
 
 
 
 
 
 

5.  Install a TERM (bus termination) jumper if required. 

See above for guidance. 
 
 

6.  Enroll the expansion module in your system. To manually 

enroll the module, use the web interface. In the advanced 
menu, navigate to 

Devices

 

– 

System Devices

 

– 

Control

 

– 

Enroll Function

 and select 

Manual Enroll

 from the 

drop down menu. This puts the system into manual 
enrollment mode. When the CPU is in the manual 
enrollment mode, simply push ENROLL button on the 
module to enroll the module into the system. Hold the 
button down for three seconds. 

 

 

 

3.  Connect the POS, NEG, LAN+ and LAN-

 

 

 

 

 

 

 

 

 

 

 

 

UM-R4  

1. Tamper input. 

Disabled by default. Connect 
tamper switch when mounted in 
a separate enclosure from CPU.  
Enable in \Devices\System 
Devices\Relay 
Expanders\Expander Options. 

 

2. Manual enroll button 
  
3. Bus and Neg/Aux jumpers. See 

below for configuration details. 

 
4. TERM (bus termination). Correct 

RS-485 termination reduces 
communication issues with 
signal reflections. For a single 
long cable run, put a jumper 
across the terminal labeled 
TERM on the 

CPU

 and the 

furthest bus device

. For 

installations with multiple long 
cable runs, (star configurations) 
do not place a terminator on the 
CPU; rather place one at the end 
of each of the 

two longest

 cable 

runs. 

UM-R10 

(pictured) 

or 

UM-R4  

4

 

 

TM 

PLEASE READ THE ULTRASYNC MODULAR HUB REFERENCE GUIDE BEFORE 
USING THIS PRODUCT WHICH INCLUDES IMPORTANT SAFETY AND LEGAL 
INFORMATION INCLUDING WARNINGS, WARRANTY DISCLAIMERS, AND 
LIMITATIONS OF LIABILITY, AND COMPLETE INSTRUCTIONS ON HOW TO ENROLL 
AND CONFIGURE EXPANSION MODULES. THE REFERENCE GUIDE IS AVAILABLE 
AT: http://www.interlogix.com/intrusion/product/ultrasync-modular-hub 
 
S'IL VOUS PLAÎT LIRE LE GUIDE DE REFERENCE POUR LE HUB UltraSync 
MODULAIRE AVANT D'UTILISER CE PRODUIT QUI COMPREND LA SÉCURITÉ 
IMPORTANT ET JURIDIQUES INFORMATIONS, Y COMPRIS LES AVERTISSEMENTS, 
GARANTIE EXCLUSIONS, ET LIMITATIONS DE RESPONSABILITÉ ET INSTRUCTIONS 
COMPLETES SUR COMMENT ENROLLER ET CONFIGURER LES MODULES 
D’EXPANSION. LE GUIDE DE RÉFÉRENCE 
EST DISPONIBLE AU: http://www.interlogix.com/intrusion/product/ultrasync-modular-hub. 