5 – 20
Section 5 • Maintenance/Service
HPLD Single Screw Compressor • Installation, Operation and Service Manual • Emerson • 35391HP
22. Check the clearance between the entire gatero-
tor blade and the shelf, rotate the gaterotor to
find the tightest spot. It should be between 0.003-
0.004“(0.076-0.102 mm). Make adjustments, if
necessary. It is preferable to shim the gaterotor
blade looser rather than tighter against the shelf,
see Figure 5-26.
23. After clearance has been set install a new O-ring
(104-2) on ball bearing housing cover, install cover
(106), and tighten the bolts (112 and 113) to the
recommended torque values.
24. Install side cover with a new gasket. Tighten the
bolts to the recommended torque value. The unit
can then be evacuated, and leak checked.
Torque values for screws:
- 110: 20 ft-lbs
- 112: 35 ft-lbs
- 113: 10 ft-lbs
- 111: 20 ft-lbs (use blue Loctite)
Figure 5-26. Check the Clearance Between the Gaterotor and Shelf
Check for 0.003 - 0.004” (0.076 - 0.102 mm) clearance between
gaterotor blade and partition
Summary of Contents for Vilter VSG128
Page 1: ...HPLD Single Screw Bare Shaft Compressor Installation Operation and Service Manual ...
Page 2: ......
Page 32: ...3 8 Blank HPLD Compressor Unit Installation Operation and Maintenance Manual Emerson 35391HPU ...
Page 68: ...6 4 Blank HPLD Compressor Unit Installation Operation and Maintenance Manual Emerson 35391HPU ...
Page 72: ...7 4 Blank HPLD Compressor Unit Installation Operation and Maintenance Manual Emerson 35391HPU ...
Page 78: ...8 6 Blank HPLD Compressor Unit Installation Operation and Maintenance Manual Emerson 35391HPU ...
Page 83: ......