5 – 21
Section 5 • Maintenance/Service
HPLD Single Screw Compressor • Installation, Operation and Service Manual • Emerson • 35391HP
101.12
101.14
101.13
101.11
Ensure gaterotor
float after assembly
Install with beveled
side facing away from
gaterotor
Gaterotor Blade Removal
1. Remove the retaining ring (101.14) and washer
(101.13) from the assembly, see Figure 5-27.
2. Lift gaterotor blade assembly (101.12) off the
gaterotor support (101.11).
3. Check damper pin and bushing for excessive wear.
Replace if required (see page 5-11 for gaterotor
float details.)
Figure 5-27. Gaterotor and Support Assembly
Gaterotor Blade Installation
1. Install bushings (101.12b) in gaterotor blade
(101.12a) from the back side of the blade. Be sure
bush ing is fully seated and torqued to 5 ft-lbs. using
red Loctite (271), see Figure 5-28.
2. Place blade assembly (101.12) on gaterotor sup-
port (101.11). Locate bushing over pin, see Figure
5-27.
3. After the gaterotor and support are assem bled,
there should be a small amount of rotational move-
ment between the gaterotor and support.
4. Install washer (101.13) and retaining ring (101.14).
NOTE
Retaining ring (101.14) must be installed with bevel
side facing away from the gaterotor, see Figure 5-27.
Figure 5-28. Gaterotor Top Face Identification
101.12a
101.12b
Top face of gaterotor
Summary of Contents for Vilter VSG128
Page 1: ...HPLD Single Screw Bare Shaft Compressor Installation Operation and Service Manual ...
Page 2: ......
Page 32: ...3 8 Blank HPLD Compressor Unit Installation Operation and Maintenance Manual Emerson 35391HPU ...
Page 68: ...6 4 Blank HPLD Compressor Unit Installation Operation and Maintenance Manual Emerson 35391HPU ...
Page 72: ...7 4 Blank HPLD Compressor Unit Installation Operation and Maintenance Manual Emerson 35391HPU ...
Page 78: ...8 6 Blank HPLD Compressor Unit Installation Operation and Maintenance Manual Emerson 35391HPU ...
Page 83: ......