SI-DeviceNet User Guide
Issue Number: 2
The mapping error codes are described in the table below:
Pr
S.01.024
and Pr
S.01.025
display the input and output processing times respectively.
The input processing time (Pr
S.01.024
) shows the time taken from the value being sent
from the drive to the value being written to the master in milliseconds. The output
processing time (Pr
S.01.025
) shows the time taken from the value being sent from the
master to the value being successfully written to the drive in milliseconds.
Value
Text
Description
0
No error
No error has been detected during mapping
initialization.
1
Par impossible
The parameter may not exist or may not be readable.
2
Hole in mapping
Cyclic data mapping parameters are not contiguous.
3
Dup mapping
Two or more cyclic data mapping configuration
parameters have been configured with the same
destination parameter reference.
4
Length exceed
The length of the mapped parameters exceeds the
length of the selected assembly object.
5
Obj not support
The selected assembly object is not supported.
6
Pre & uncompress
If the predefined object is selected, the data alignment
must be set to 16 bits.
7
Type unmatched
The IN and OUT objects both must be predefined
objects, or neither.
8
Memory fault
Failed to allocate memory for mapping.
9
No mapping
No parameter is assigned to the mapping.
10
Reserved
Reserved
Input processing time
S.01.024
Default
N/A
Range
0 to 65535 ms
Access
RO
Output processing time
S.01.025
Default
N/A
Range
0 to 65535 ms
Access
RO