Figure 4-1: Roxar Double Block Service Valve installed in 6 o'clock position
Close and open both balls to ensure enough operation clearance. Ensure that both
balls in the valve are fully open and that the by-pass valves and the bleed off valve
are closed.
7. With the retriever standing on the ground, expand the inner barrel fully by pulling
the hammer nut out (refer to the expanded retriever on the right of
Ensure it turns smoothy without sticking or catching: if the retriever does not turn
smoothly, it might require lubrication.
Note
If the access fitting is mounted at the 12 o'clock position, consider using the safety
clamp to avoid the retriever collapsing when mounted on the service valve. For the
3, 6, or 9 o'clock positions, the retriever can be mounted directly without the need
for the safety clamp.
User Manual
Operating instructions
ROX000295904
June 2020
www.Emerson.com/Roxar
27
Summary of Contents for Roxar
Page 1: ...User Manual ROX000295904 Rev AC June 2020 Roxar Mechanical Retrieval Tool User Manual ...
Page 2: ...2 ...
Page 4: ...Contents User Manual June 2020 ROX000295904 4 www Emerson com Roxar ...
Page 20: ...Technical description User Manual June 2020 ROX000295904 20 www Emerson com Roxar ...
Page 34: ...Operating instructions User Manual June 2020 ROX000295904 34 www Emerson com Roxar ...
Page 45: ...User Manual Attachments ROX000295904 June 2020 www Emerson com Roxar 45 ...