4. Locate the Rosemount 708 Transmitter and high temperature mounting hardware
on a horizontal section of the piping as close as possible to the equipment being
monitored.
5. Ensure the mounting location is free of foreign matter and corrosion to ensure good
contact between the piping and mounting hardware.
6. Insert the U-bolt through the standoff mounting hardware.
7. Tighten each nut to 90 in-lb (10 N-m)
.
8. If commissioning the device, install the power module (see
9. Ensure the power module cover is fully tightened to prevent moisture ingress. The
lip of the polymer power module cover should be in contact with the surface of the
polymer enclosure to ensure a proper seal. Do not over tighten.
Example
Figure 3-6: High Temperature Mounting Hardware
Reference Manual
Installation
00809-0100-4708
June 2022
Rosemount 708 Wireless Acoustic Transmitter Reference Manual
19