background image

Reference Manual

00809-0100-4708, Rev DB

June 2022

Rosemount

 708 Wireless Acoustic

Transmitter

Summary of Contents for Rosemount 708

Page 1: ...Reference Manual 00809 0100 4708 Rev DB June 2022 Rosemount 708 Wireless Acoustic Transmitter ...

Page 2: ... wireless products The unit was shipped to you without the power module installed Remove the power module prior to any re shipping Each power module contains one D size primary lithium battery Primary lithium batteries are regulated in transportation by the U S Department of Transportation and are also covered by IATA International Air Transport Association ICAO International Civil Aviation Organi...

Page 3: ...inaccurate readings For information on Rosemount nuclear qualified products contact your local Emerson Sales Representative CAUTION Install and tighten process connectors before applying pressure Avoid contact with the leads and terminals High voltage that may be present on leads can cause electrical shock If the sensor is installed in a high voltage environment and a fault or installation error o...

Page 4: ...ance of 8 in 20 cm from all persons WARNING Physical access Unauthorized personnel may potentially cause significant damage to and or misconfiguration of end users equipment This could be intentional or unintentional and needs to be protected against Physical security is an important part of any security program and fundamental to protecting your system Restrict physical access by unauthorized per...

Page 5: ...n and Maintenance 27 5 1 Safety messages 27 5 2 Operation 27 5 3 Alerts 28 5 4 Power module replacement 32 Chapter 6 Troubleshooting 33 6 1 Overview 33 6 2 Safety messages 33 6 3 Maintenance and troubleshooting suggestions 33 6 4 Opening the lid cover 35 Appendix A Specifications and Reference Data 37 A 1 Functional specifications 37 A 2 Physical specifications 37 A 3 Performance specifications 38...

Page 6: ...th America 43 B 6 USA 44 B 7 Canada 44 B 8 Europe 44 B 9 International 45 B 10 Brazil 45 B 11 China 45 B 12 Japan 45 B 13 EAC Belarus Kazakhstan Russia 46 B 14 Korea 46 Appendix C Recommended Wireless Network Practices 47 C 1 Effective range 47 Contents Reference Manual June 2022 00809 0100 4708 6 Rosemount 708 Wireless Acoustic Transmitter Reference Manual ...

Page 7: ...ntenance contains operation and maintenance techniques Troubleshooting provides troubleshooting techniques for the most common operating problems Specifications and Reference Data supplies reference and specification data as well as ordering information Product Certifications contains intrinsic safety approval information European ATEX directive information and approval drawings Recommended Wirele...

Page 8: ...Overview Reference Manual June 2022 00809 0100 4708 8 Rosemount 708 Wireless Acoustic Transmitter Reference Manual ...

Page 9: ...jury Use extreme caution when making contact with the leads and terminals Device must be installed to ensure a minimum antenna separation distance of 8 in 20 cm from all persons 2 2 Device configuration Remove the power module cover and connect to the HART Communication terminals for configuration The Rosemount 708 Acoustic Wireless Transmitter will receive HART Communication from a Field Communic...

Page 10: ...s Network Network Settings page on the web server shown in Figure 2 1 Figure 2 1 Gateway Network Settings 2 3 1 Configure the network using AMS Device Manager Procedure 1 Right click on the acoustic transmitter and select Configure 2 When the menu opens select Join Device to Network and follow the method to enter the network ID and join key 2 3 2 Field Communicator The network ID and join key may ...

Page 11: ...onfigure Update Rates Alert Setup Manual Setup 2 2 Wireless Sensor HART Security Device Information Power Wireless 2 2 1 Network ID Join Device to Network Broadcast Information 2 4 Remove power module Procedure After the device has been configured remove the power module and replace the power module cover The power module should be inserted only when the device is ready for commissioning Reference...

Page 12: ...2 5 HART menu tree Figure 2 2 Field Communicator Menu Tree Configuration Reference Manual June 2022 00809 0100 4708 12 Rosemount 708 Wireless Acoustic Transmitter Reference Manual ...

Page 13: ...ous injury Use extreme caution when making contact with the leads and terminals Device must be installed to ensure a minimum antenna separation distance of 8 in 20 cm from all persons 3 2 Considerations 3 2 1 General The Rosemount 708 Acoustic Wireless Transmitter measures the level of ultrasonic acoustic noise and waveguide temperature The Rosemount 708 Transmitter converts the acoustic and tempe...

Page 14: ...ately 1 m 3 ft from any large structure building or conductive surface to allow for clear communication to other devices Refer to best practices for additional information on optimal mounting locations of device Figure 3 2 Antenna Position Recommended practices When mounting the device recommended practices should be considered to achieve the best wireless performance Related information Recommend...

Page 15: ...e Field Communicator to the transmitter Figure 3 3 Connection Diagram 3 2 3 Mechanical Location When choosing a location and position consider access to the power module compartment for easy power module replacement Electronics cover The electronics cover is sealed and cannot be removed Do not attempt to unscrew the cover 3 2 4 Electrical Power module The Rosemount 708 Transmitter is self powered ...

Page 16: ... process is transferred to the transmitter housing If the process temperature is high the ambient temperature will need to be lower to account for heat transferred to the transmitter housing See Table 3 1 for ambient temperature derating Refer to Table 3 2 for High Temperature option HT01 for ambient temperature derating Table 3 1 Ambient Temperature Derating Process temperature Max ambient C F C ...

Page 17: ...uld be affected by stress corrosion and potentially fail when in the presence of chlorides 6 The transmitter should be installed such that steam or other high temperature fluids do not directly impinge the housing of the device 7 If installing the device on a steam trap the device should be installed on the upstream side of the trap 3 3 Mounting For high temperature mounting see Mounting in a high...

Page 18: ... order of proximity from the Gateway beginning with the closest device to the Gateway This will result in faster network formation 3 3 1 Mounting in a high temperature application High temperature mounting hardware should be used when process temperatures exceed 260 C 500 F Procedure 1 Place the foot of the transmitter between the standoff mounting hardware plates as shown in Figure 3 6 2 Press st...

Page 19: ...doff mounting hardware 7 Tighten each nut to 90 in lb 10 N m Figure 3 7 8 If commissioning the device install the power module see Figure 3 5 9 Ensure the power module cover is fully tightened to prevent moisture ingress The lip of the polymer power module cover should be in contact with the surface of the polymer enclosure to ensure a proper seal Do not over tighten Example Figure 3 6 High Temper...

Page 20: ...e Mounting Kit A B A For pipe sizes to 1 in B Bracket mounting Dimensions are in inches millimeters Figure 3 8 Piping Insulation Side View Installation Reference Manual June 2022 00809 0100 4708 20 Rosemount 708 Wireless Acoustic Transmitter Reference Manual ...

Page 21: ...y that the operating environment of the device is consistent with the appropriate hazardous locations certifications Electrical shock could cause death or serious injury Use extreme caution when making contact with the leads and terminals Device must be installed to ensure a minimum antenna separation distance of 8 in 20 cm from all persons 4 2 Verify operation There are three methods available to...

Page 22: ...lable Neighbors Number of Advertisements Heard Number of Join Attempts 4 2 2 Emerson Wireless Gateway Using the Gateway s web interface navigate to the Devices page as shown in Figure 4 1 Locate the device in question and verify all status indicators are good green Figure 4 1 Emerson Wireless Gateway Explorer page AMS Device Manager When the device has joined the network it will appear in the AMS ...

Page 23: ...t Active Advertising has been enabled on the Gateway The network ID and join key in the device must match the network ID and join key of the Gateway The network ID and join key may be obtained from the Gateway on the System Settings Network Network Settings page of the web server see Figure 4 3 The network ID and join key may be changed in the wireless device by following the Fast Key sequence sho...

Page 24: ...tly used to interrogate and configure the device Table 4 1 Rosemount 708 Fast Key Sequence Function Key sequence Menu items Device Information 2 2 5 Tag Long Tag Descriptor Message Date Country SI Unit Control Guided Setup 2 1 Basic Setup Join Device to Network Configure Update Rates Alert Setup Manual Setup 2 2 Wireless Sensor HART Security Device Information Power Wireless 2 2 1 Network ID Join ...

Page 25: ...Figure 4 4 Field Communicator Connections Reference Manual Commissioning 00809 0100 4708 June 2022 Rosemount 708 Wireless Acoustic Transmitter Reference Manual 25 ...

Page 26: ...Commissioning Reference Manual June 2022 00809 0100 4708 26 Rosemount 708 Wireless Acoustic Transmitter Reference Manual ...

Page 27: ...ons 5 2 Operation The Rosemount 708 Acoustic Wireless Transmitter measures ultrasonic acoustic energy and waveguide temperature The acoustic level is reported in counts which are a relative indication of the magnitude The sensor used in the Rosemount 708 Transmitter is sensitive to a broad range of frequencies to work in many different applications The acoustic measurement or count in the transmit...

Page 28: ...nformation on these alerts refer to Troubleshooting The following figures show how the AMS Device Manager overview screen looks for each of the alert conditions Figure 5 1 AMS Device Manager Overview Screen Normal Conditions Figure 5 2 AMS Device Manager Overview Screen Alert Conditions Operation and Maintenance Reference Manual June 2022 00809 0100 4708 28 Rosemount 708 Wireless Acoustic Transmit...

Page 29: ...onfigured threshold Alert setup The alerts are configured using AMS Device Manager or a Field Communicator Figure 5 3 Alert Setup Screen Install and learn To use the install and learn function the device must be installed and the equipment being monitored must be in its normal state Procedure 1 After configuration and operating conditions have been confirmed go to the configuration menu under guid...

Page 30: ...nction use the Manual or Guided user alert setup to set alerts Figure 5 4 Install and Learn Alert Setup Screen Guided user alert setup Guided user alert setup cycles through on screen prompts to set the alert levels At each screen the current level will be shown along with a field to enter the desired alert level as seen in Figure 5 5 Procedure 1 To use the guided alert setup navigate to the confi...

Page 31: ... under the main configuration menu 2 Enter the desired alert levels for each alert as shown in Figure 5 6 Figure 5 6 Manual Alert Setup Screen 3 If a device is installed and shows an unexpected alert verify the configuration conditions Reference Manual Operation and Maintenance 00809 0100 4708 June 2022 Rosemount 708 Wireless Acoustic Transmitter Reference Manual 31 ...

Page 32: ...ON Use caution when handling the power module it may be damaged if dropped from heights in exceeding 6 1 meters 20 feet Battery hazards remain when cells are discharged Environmental considerations As with any battery local environmental rules and regulations should be consulted to properly manage spent batteries If no specific requirements exist recycling through a qualified recycler is encourage...

Page 33: ...d personnel perform the installation Explosions could result in death or serious injury Before connecting a handheld communicator in an explosive atmosphere ensure the instruments are installed in accordance with intrinsically safe or non incendive field wiring practices Verify that the operating environment of the device is consistent with the appropriate hazardous locations certifications Electr...

Page 34: ...ure exceeded the limits 1 Verify ambient temperature is within the transmitter s range 2 Reset the device 3 If the condition persists replace the device Waveguide Temperature exceeded the limits 1 Verify process temperature is within the transmitter s range 2 Reset the device 3 If the condition persists replace the device Supply Voltage Low 1 Replace the power module Database Memory Warning 1 Rese...

Page 35: ...ce has power 2 Verify the device is within effective communications range 3 Verify the proper Network ID has been entered into the device 4 See troubleshooting section of the Emerson Wireless Gateway Reference Manual for more information Limited Bandwidth Error 1 Use the slowest acceptable update rate 2 Increase communication paths by adding more wireless points 3 Check that the device has been on...

Page 36: ...Troubleshooting Reference Manual June 2022 00809 0100 4708 36 Rosemount 708 Wireless Acoustic Transmitter Reference Manual ...

Page 37: ...e Replaceable non rechargeable Intrinsically Safe Lithium Thionyl Chloride power module pack with PBT PC enclosure Ten year power module life at reference conditions Note Reference conditions are 21 C 70 F transmit rate of once per minute and routing data for three additional network devices A 2 2 Field Communicator connections Communication Terminals Clips permanently fixed to power module A 2 3 ...

Page 38: ...pecifications A 3 1 Vibration effect Tested per the requirements of IEC60770 1 field or pipeline with high vibration level 10 60 Hz 0 21 mm displacement peak amplitude 60 2000 Hz 3g A 3 2 Temperature limits Ambient Limit 40 to 85 C 40 to 185 F Storage Limit 40 to 85 C 40 to 185 F Table A 1 Temperature Derating Process temperature C Max ambient C 260 41 240 45 220 49 200 53 180 57 160 61 140 64 120...

Page 39: ...lectromagnetic Compatibility EMC All models meet all relevant requirements of EN 61326 2 3 2006 A 4 Wireless output specifications Acoustic level output 0 255 counts Temperature output 40 to 260 C 40 to 500 F Reference Manual Specifications and Reference Data 00809 0100 4708 June 2022 Rosemount 708 Wireless Acoustic Transmitter Reference Manual 39 ...

Page 40: ...sent the most common options and should be selected for best delivery The non starred offerings are subject to additional delivery lead time Model Product description 708 Acoustic Transmitter Output protocol X Wireless Measurement 1 Steam Traps with SteamLogic software 2 Other Measurements Specifications and Reference Data Reference Manual June 2022 00809 0100 4708 40 Rosemount 708 Wireless Acoust...

Page 41: ...550 C Table A 4 Wireless options include with selected model number The starred offerings represent the most common options and should be selected for best delivery The non starred offerings are subject to additional delivery lead time Wireless update rate operating frequency and protocol WA3 User Configurable Update Rate 2 4 GHz DSSS IEC 62591 WirelessHART Omni directional wireless antenna and Sm...

Page 42: ...Specifications and Reference Data Reference Manual June 2022 00809 0100 4708 42 Rosemount 708 Wireless Acoustic Transmitter Reference Manual ...

Page 43: ...mful interference This device must accept any interference received including interference that may cause undesired operation This device must be installed to ensure a minimum antenna separation distance of 20 cm from all persons B 4 Ordinary Location Certification As standard the transmitter has been examined and tested to determine that the design meets the basic electrical mechanical and fire p...

Page 44: ... 2 No 60529 05 Markings I S CL I DIV 1 GP A B C D when installed per Rosemount drawing 00708 1001 T3C Type 4X B 8 Europe I1 ATEX Intrinsic Safety Certificate Baseefa11ATEX0174X Standards EN 60079 0 2012 EN 60079 11 2012 Markings II 1 G Ex ia IIC T4 Ga T4 40 C Ta 70 C Special Conditions for Safe Use X 1 The plastic enclosure of the Rosemount 708 may constitute a potential electrostatic ignition ris...

Page 45: ... ABNT NBR IEC 60079 0 2008 Errata 1 2011 ABNT NBR IEC 60079 11 2009 Markings Ex ia IIC T4 Ga T4 40 C Ta 70 C Special Condition for Safe Use X 1 See certificate for special conditions B 11 China I3 China Intrinsic Safety Certificate GYJ13 1445X Standards GB3836 1 2010 GB3836 4 2010 GB3836 20 2010 Markings Ex ia IIC Ga T4 40 70 C Special Condition for Safe Use X 1 See certificate for special conditi...

Page 46: ...cial Condition for Safe Use X 1 See certificate for special conditions B 14 Korea IP Korea Intrinsic Safety Certificate 13 KB4BO 0145X Markings Ex ia IIC T4 T4 40 C Ta 70 C Special Condition for Safe Use X 1 See certificate for special conditions Product Certifications Reference Manual June 2022 00809 0100 4708 46 Rosemount 708 Wireless Acoustic Transmitter Reference Manual ...

Page 47: ...e devices around the gateway and ensures fewer hops and more bandwidth available to WirelessHART devices with fast scan rates 5 Minimize the path distance from the gateway For better performance the path is typically within range of one or two hops This will utilize path redundancy and create very short transit times 6 Determine effective range by type of process unit and density of the infrastruc...

Page 48: ...ll rights reserved Emerson Terms and Conditions of Sale are available upon request The Emerson logo is a trademark and service mark of Emerson Electric Co Rosemount is a mark of one of the Emerson family of companies All other marks are the property of their respective owners ...

Reviews: