Specifications and Reference Data
77
Specifications and Reference Data
May 2017
Reference Manual
00809-0700-4001, Rev AA
CN
Analog output levels compliant with NAMUR recommendation NE 43, low alarm
★
CR
Custom alarm and saturation signal levels, high alarm (requires C1 and Configuration Data Sheet)
★
CS
Custom alarm and saturation signal levels, low alarm (requires C1 and Configuration Data Sheet)
★
CT
Low alarm (standard Rosemount alarm and saturation levels)
★
Extended product warranty
WR3
3-year warranty
WR5
5-year warranty
HART revision configuration
HR5
(10)
Configured for HART Revision 5
★
HR7
(11)
Configured for HART Revision 7
★
Surface finish
Q16
Surface finish certification for sanitary remote seals
★
Toolkit total system performance reports
QZ
Remote seals system performance calculation report
★
Conduit electrical connection
GE
M12, 4-pin, male connector (eurofast
®
)
★
GM
A size mini, 4-pin, male connector (minifast
®
)
★
NACE certificate
(12)
Q15
Certificate of compliance to NACE
®
MR0175/ISO 15156 for wetted materials
★
Q25
Certificate of compliance to NACE MR0103 for wetted materials
★
Stainless steel tagging
Y2
316SST Nameplates, Labels, Tags, and Fasteners
Typical model number:
3051P P 5 F 2A 2 1 A HR5 B4
1.
Materials of Construction comply with recommendations per NACE MR0175/ISO 15156 for sour oil field production environments. Environmental limits apply to certain
materials. Consult latest standard for details. Selected materials also conform to NACE MR0103 for sour refining environments.
2.
“Assemble-to” items are specified separately and require a completed model number.
3.
Panel mounting bolts are not supplied.
4.
Consult an Emerson Representative for availability of Product Certifications.
5.
Not available with assemble-to manifold (S5 code), assemble-to seal (S1 code), surface finish certification (Q16 code), remote seal system report (QZ code).
6.
Not valid with alternate process connection S5.
7.
Transmitter is shipped with 316 SST conduit plug (uninstalled) in place of standard carbon steel conduit plug.
8.
The V5 option is not needed with the T1 option; external ground screw assembly is included with the T1 option.
9.
Select Configuration Buttons (option code D4 or DZ) if local configuration buttons are required.
10. Configures the HART output to HART Revision 5. The device can be field configured to HART Revision 7 if needed.
Table A-2. Rosemount 3051P In-Line Pressure Transmitter Ordering Information
The starred offerings (
★
) represent the most common options and should be selected for best delivery. The non-starred offerings are subject to
additional delivery lead time.
Summary of Contents for Rosemount 3051P
Page 2: ......
Page 8: ...6 Reference Manual 00809 0700 4001 Rev AA Contents May 2017 Contents ...
Page 12: ...2 Reference Manual 00809 0700 4001 Rev AA Introduction May 2017 Introduction ...
Page 36: ...26 Reference Manual 00809 0700 4001 Rev AA Configuration May 2017 Configuration ...
Page 74: ...64 Reference Manual 00809 0700 4001 Rev AA Troubleshooting May 2017 Troubleshooting ...
Page 109: ......