Multiple analog output block
The Multiple Analog Output Block (MAO_1400 to MAO_1700) accepts output values from field devices
and assigns them to specified I/O channels in order to make them available for the display.
Table C-7. Multiple Analog Output Block
Index
Number
Parameter
Description
1
ST_REV
The revision level of the static data associated with the function block.
The revision value increments each time a static parameter value in the
block is changed.
2
TAG_DESC
The user description of the intended application of the block.
3
STRATEGY
The strategy field can be used to identify grouping of blocks. This data
is not checked or processed by the block.
4
ALERT_KEY
The identification number of the plant unit. This information may be
used in the host for sorting alarms, etc.
5
MODE_BLK
The actual, target, permitted, and normal modes of the block.
Target: The mode to “go to”
Actual: The mode the “block is currently in”
Permitted: Allowed modes that target may take on
Normal: Most common mode for target
6
BLOCK_ERR
This parameter reflects the error status associated with the hardware
or software components associated with a block. It is a bit string, so
that multiple errors may be shown.
7
CHANNEL
Defines the output that drives the field device.
8
IN_1
Numbered input parameter for multiple output function blocks
9
IN_2
Numbered input parameter for multiple output function blocks
10
IN_3
Numbered input parameter for multiple output function blocks
11
IN_4
Numbered input parameter for multiple output function blocks
12
IN_5
Numbered input parameter for multiple output function blocks
13
IN_6
Numbered input parameter for multiple output function blocks
14
IN_7
Numbered input parameter for multiple output function blocks
15
IN_8
Numbered input parameter for multiple output function blocks
16
MO_OPTS
Options that the user may select to alter multiple output block
processing. In case a Fault State option is set, the 2230 will send a Field
Diagnostic alert.
17
FSTATE_TIME
18
FSTATE_VAL1
The preset analog value to use when failure occurs in IN_1. Ignored if
the “Fault state to value 1” in the MO_OPTS parameter is false.
19
FSTATE_VAL2
The preset analog value to use when failure occurs in IN_2. Ignored if
the “Fault state to value 2” in the MO_OPTS parameter is false.
20
FSTATE_VAL3
The preset analog value to use when failure occurs in IN_3. Ignored if
the “Fault state to value 3” in the MO_OPTS parameter is false.
21
FSTATE_VAL4
The preset analog value to use when failure occurs in IN_4. Ignored if
the “Fault state to value 4” in the MO_OPTS parameter is false.
Summary of Contents for Rosemount 2230
Page 1: ...Reference Manual 00809 0100 2230 Rev CA July 2017 Rosemount 2230 Graphical Field Display ...
Page 2: ......
Page 4: ...ii Reference Manual 00809 0100 2230 Rev CA Title Page July 2017 Title Page ...
Page 16: ...6 Reference Manual 00809 0100 2230 Rev CA Introduction July 2017 Introduction ...
Page 28: ...18 Reference Manual 00809 0100 2230 Rev CA Overview July 2017 Overview ...
Page 44: ...34 Reference Manual 00809 0100 2230 Rev CA Installation July 2017 Installation ...
Page 154: ...144 Reference Manual 00809 0100 2230 Rev CA Index July 2017 Index ...
Page 155: ......