11 CAUSE AND REMEDY OF OPERATING 
FAULTS

If the valve function or operating action is 
faulty, a check should be made to ensure that 
the assembly and installation work has been 
carried out and completed in accordance with 
the installation and maintenance instructions.
The information relating to material, pressure, 
temperature and direction of flow should be 
compared with the installation diagram of the 
pipeline system. Furthermore, a check should 
be made on whether the installation conditions 
correspond to the technical data given in the 
data sheet or on the rating plate.

The safety regulations must always 
be observed when troubleshooting.
Repair work must only be carried out by 
the manufacturer’s trained personnel.

12 DECOMMISSIONING

Removal of the valve for repair or servicing is 
often carried out carelessly, as the valve has to 
be repaired or replaced in any case. However, it 
is recommended that the valve is removed with 
care, without damaging the PTFE, so that the 
possible cause of damage can be determined 
after removal.

13 SPARE PARTS

Always provide the information in accordance 
with the rating plate fitted on the mounting 
flange when ordering seals and other 
spare parts.

14 DISPOSAL

Hand in the correctly cleaned valve to the 
scrap material recycling plant.

Badly cleaned valves can cause severe burning 
of the hands and other parts of the body.

If the valve is passed on to a third party, the 
manufacturer no longer guarantees the valve.

10 SERVICING AND MAINTENANCE

No routine maintenance or lubrication is 
required. However, for systems with high 
temperatures, an inspection for leakage at 
the flanges should be carried out shortly after 
installation. The large difference between 
the temperature related expansions of PTFE 
and some metals can result in cold flow. 
Tightening the bolts once again will eliminate 
this problem. This process may possibly have to 
be repeated several times. We recommend that 
the valve is operated at least once a month.

ATTENTION!

Check that the pipe is depressurized and drained. 
With corrosive, inflammable, aggressive or toxic 
media, ventilate the pipeline system.

- Only allow assembly work to be carried out 

by qualified personnel.

- Almost fully close the valve (note position 

of the flat sections of the control shaft).

- Loosen all flange bolts and withdraw 

them until the valve can be removed.

- Spread the flanges apart using a suitable 

tool and withdraw the valve.

Summary of Contents for Neotecha NTB

Page 1: ...hat the user is qualified to Qualified Personnel level Operating staff must be given appropriate training in the operating and maintenance instructions 2 SAFETY Please also read through these notes carefully 2 1 General potential danger due to a Failure to observe the instructions b Improper use c Insufficiently qualified personnel 2 2 Correct use 2 2 1 Area of application Ball valves are bubble t...

Page 2: ...utions should be taken to protect against burns due to high or freezing temperatures In particular insulated gloves should be worn when using the hand lever for example In case of fire the mechanical strength of the PTFE seals is no longer guaranteed above 200 C 2 2 5 Usage restrictions Before the valve is installed a check should be made on the extent to which the coating of the surfaces is resis...

Page 3: ... information should be carefully noted down each time Ball valves in the size range DN 15 to DN 25 have a standard rating plate with no CE mark Ball valves in the size range DN 40 to DN 150 are provided with a rating plate with a CE mark Additional identification on the valve in accordance with DIN 19 such as DN PN manufacturer s logos of the Neotecha AG company The identification of the valve bod...

Page 4: ... the hand lever can be provided with limit switches which indicate open or closed For installation in exposed places shaft extensions in various lengths are available for all sizes 6 6 Bolted joints in the pipeline All flange bolts must be used even on low pressure systems The specified tightening toques for the bolts must always be adhered to 6 7 Body variants NTB and NTC ball valves have the sam...

Page 5: ... mm inches Nm 6 9 1 Recommended tightening torques for NTB NTC ball valves DIN PN 16 and JIS 10K RECOMMENDED TORQUES DN Bolts Class Torque mm inches UNC lbf ft 6 9 2 Recommended tightening torques for NTB NTC ball valves ANSI B 16 10 class 150 lbs 6 8 Step by step valve installation 1 Check that the distance between flanges matches the face to face dimension of the ball valve Before installing the...

Page 6: ...t is installed or existing protective equipment repaired 9 USE 9 1 Operation general NTB series ball valves should only be used in the fully open or fully closed position as they are not designed for flow regulation Intermediate settings can result in turbulence leading to vibrations in the pipeline system which then generates noise If the flow has to be regulated an NTC series C valve should be u...

Page 7: ...the information in accordance with the rating plate fitted on the mounting flange when ordering seals and other spare parts 14 DISPOSAL Hand in the correctly cleaned valve to the scrap material recycling plant Badly cleaned valves can cause severe burning of the hands and other parts of the body If the valve is passed on to a third party the manufacturer no longer guarantees the valve 10 SERVICING...

Page 8: ...son logo are trademarks and service marks of Emerson Electric Co All other marks are the property of their respective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or the...