background image

2

NEOTECHA

 NTB-NTC BALL VALVES

INSTALLATION AND MAINTENANCE INSTRUCTIONS

Angular 

position

2.2.4 Flow characteristic for NTC control valves 
(without control orifice plate)

3 SOURCES OF DANGER

3.1 External chemical effects

The valve body is either made of stainless steel 
or is coated with a 2-part polyester paint. The 
coating can be attacked externally by strong 
solvents, leading to corrosion of the body. 
If damage of this nature occurs, the effects 
on the environment should be investigated 
and the damage to the coating made good 
in accordance with the manufacturer’s data. 
Stainless steel valve bodies are not suitable 
for use with chlorine gas.

3.2 Mechanical

When using hand levers and handwheels, 
it should be ensured that there is sufficient 
clearance everywhere for the operator’s 
hands, so that there is no risk of trapping.

3.3 Electrical

If static charges can lead to explosions, 
the valve must be earthed by means of 
the appropriate earthing accessory. As an 
alternative, valves with electrically conductive 
linings are available. For more information, 
please contact the supplier or manufacturer.

3.4 Thermal

The operating temperature of the valve can 
be up to a maximum of 200°C. Suitable 
precautions should be taken to protect against 
burns due to high or freezing temperatures. 
In particular, insulated gloves should be worn 
when using the hand lever, for example. In case 
of fire, the mechanical strength of the PTFE 
seals is no longer guaranteed above 200°C.

2.2.5 Usage restrictions

Before the valve is installed, a check should be 
made on the extent to which the coating of the 
surfaces is resistant to the intended medium. 
The same applies to stainless steel valves with 
no additional coating. Refer to appropriate 
literature or consult the manufacturer or 
distributor for advice on this.

2.2.6 Modification prohibition

Mechanical modifications to the valves or the 
use of other manufacturer’s parts for repair 
purposes are not permissible, as otherwise 
safety is no longer guaranteed. Repair work 
must only be carried out by the manufacturer’s 
trained personnel. The manufacturer and 
supplier will accept no liability in the event 
of misuse.

bar

Vacuum

0.1 mbar

2.2.3 Pressure-temperature diagram for 
NTB-NTC ball valves

2.2.7 Warning about foreseeable misuse

Valves and their accessories (e.g. operating 
elements) must not be misused as 
climbing aids.

2.2.8 Duty to comply with the instructions 
for operation, maintenance and servicing

These instructions form part of the delivery 
package and must be easily accessible to the 
user. They should be protected from soiling 
and kept in a suitable place.

Summary of Contents for Neotecha NTB

Page 1: ...hat the user is qualified to Qualified Personnel level Operating staff must be given appropriate training in the operating and maintenance instructions 2 SAFETY Please also read through these notes carefully 2 1 General potential danger due to a Failure to observe the instructions b Improper use c Insufficiently qualified personnel 2 2 Correct use 2 2 1 Area of application Ball valves are bubble t...

Page 2: ...utions should be taken to protect against burns due to high or freezing temperatures In particular insulated gloves should be worn when using the hand lever for example In case of fire the mechanical strength of the PTFE seals is no longer guaranteed above 200 C 2 2 5 Usage restrictions Before the valve is installed a check should be made on the extent to which the coating of the surfaces is resis...

Page 3: ... information should be carefully noted down each time Ball valves in the size range DN 15 to DN 25 have a standard rating plate with no CE mark Ball valves in the size range DN 40 to DN 150 are provided with a rating plate with a CE mark Additional identification on the valve in accordance with DIN 19 such as DN PN manufacturer s logos of the Neotecha AG company The identification of the valve bod...

Page 4: ... the hand lever can be provided with limit switches which indicate open or closed For installation in exposed places shaft extensions in various lengths are available for all sizes 6 6 Bolted joints in the pipeline All flange bolts must be used even on low pressure systems The specified tightening toques for the bolts must always be adhered to 6 7 Body variants NTB and NTC ball valves have the sam...

Page 5: ... mm inches Nm 6 9 1 Recommended tightening torques for NTB NTC ball valves DIN PN 16 and JIS 10K RECOMMENDED TORQUES DN Bolts Class Torque mm inches UNC lbf ft 6 9 2 Recommended tightening torques for NTB NTC ball valves ANSI B 16 10 class 150 lbs 6 8 Step by step valve installation 1 Check that the distance between flanges matches the face to face dimension of the ball valve Before installing the...

Page 6: ...t is installed or existing protective equipment repaired 9 USE 9 1 Operation general NTB series ball valves should only be used in the fully open or fully closed position as they are not designed for flow regulation Intermediate settings can result in turbulence leading to vibrations in the pipeline system which then generates noise If the flow has to be regulated an NTC series C valve should be u...

Page 7: ...the information in accordance with the rating plate fitted on the mounting flange when ordering seals and other spare parts 14 DISPOSAL Hand in the correctly cleaned valve to the scrap material recycling plant Badly cleaned valves can cause severe burning of the hands and other parts of the body If the valve is passed on to a third party the manufacturer no longer guarantees the valve 10 SERVICING...

Page 8: ...son logo are trademarks and service marks of Emerson Electric Co All other marks are the property of their respective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or the...

Reviews: