background image

3

NEOTECHA

 NTB-NTC BALL VALVES

INSTALLATION AND MAINTENANCE INSTRUCTIONS

3.5 Requirements for the operator

This means people who are familiar with the 
erection, installation, commissioning, operation 
and maintenance of the product and have 
appropriate qualifications relating to their 
activities and functions, such as e.g.:
- Instruction in and duty to comply with all 

installation-related, regional and internal 
works regulations and requirements.

- Training or instruction in accordance with the 

Safety Standards for personal care and use of 
appropriate safety equipment and protective 
workgear, like e.g. personal protection 
equipment (insulated gloves or similar), 
suitable for the operating conditions.

Furthermore, these people must have read 
and understood these instructions.

3.6 Transport/storage

The valve is delivered with protective covers 
which should protect against soiling and 
mechanical effects. For this reason, the 
protective covers should only be removed 
immediately prior to installation.
The ball valve is shipped in the closed position.

3.7 Transport and storage conditions

- Transport and storage temperature 

-20°C to +65°C.

- Protect against external force(impact, 

shock, vibration).

- Do not damage the coating.
- In damp storage areas, a drying agent 

or heating is required to protect against 
condensation.

- Store the ball valve in a slightly open position.

3.8 Handling prior to installation

- On versions with protective covers, 

only remove these immediately prior 
to installation!

- Protect against the effects of weather, 

e.g. dampness (or else use a drying agent).

- Proper treatment prevents damage.

4 IDENTIFICATION

Each ball valve is fitted with a rating plate giving 
information on valve type and origin. When 
ordering spare parts this information should 
be carefully noted down each time.
Ball valves in the size range DN 15 to DN 25 
have a standard rating plate with no CE mark. 
Ball valves in the size range DN 40 to DN 150 
are provided with a rating plate with a CE mark.
Additional identification on the valve in 
accordance with DIN 19, such as: DN, PN, 
manufacturer’s logos of the Neotecha AG 
company        . The identification of the valve 
body material is cast onto the valve.

5 DIMENSIONS AND WEIGHTS

Please refer to the product documentation 
for any dimensions that are not contained in 
the installation and maintenance instructions 
and for ball valve weights.

6 INSTALLATION

6.1 Installation in the pipeline

Fit the ball valve in the pipeline, ensuring that 
the sealing surfaces on the faces of the flanges 
are not damaged. The NTB ball valve can be 
installed independently of the direction of 
flow. On the other hand, the NTC can only be 
installed in one direction, i.e. the arrow on the 
side of the valve must point in the direction of 
flow. Adequate clearance should be ensured 
around the ball valve, so that it can be operated 
and maintained easily.
The mounting flanges of the pipeline in which 
the valve is to be installed must be aligned 
axially and laterally, in order to prevent the 
valve body being subjected to additional 
stresses. Fit suitable flange packings, provided 
that they are called for: then the fixing bolts 
are inserted. Tightening the bolts in stages is 
essential for an equal distribution of the of the 
initial stress force of the clamping bolts.
The specified tightening torques must not 
be exceeded.

The flanges must meet the following 
requirements: cleaned and undamaged 
mating surface.

Flange packings are not required with flanges 
with flat sealing surfaces. Additional packings 
may possibly be required with rubberized 
flanges.

Manufacturer

Origin

Serial number

Manufacturer’s code

Ball valve type

Year of manufacture

Number of the 

notified body

Summary of Contents for Neotecha NTB

Page 1: ...hat the user is qualified to Qualified Personnel level Operating staff must be given appropriate training in the operating and maintenance instructions 2 SAFETY Please also read through these notes carefully 2 1 General potential danger due to a Failure to observe the instructions b Improper use c Insufficiently qualified personnel 2 2 Correct use 2 2 1 Area of application Ball valves are bubble t...

Page 2: ...utions should be taken to protect against burns due to high or freezing temperatures In particular insulated gloves should be worn when using the hand lever for example In case of fire the mechanical strength of the PTFE seals is no longer guaranteed above 200 C 2 2 5 Usage restrictions Before the valve is installed a check should be made on the extent to which the coating of the surfaces is resis...

Page 3: ... information should be carefully noted down each time Ball valves in the size range DN 15 to DN 25 have a standard rating plate with no CE mark Ball valves in the size range DN 40 to DN 150 are provided with a rating plate with a CE mark Additional identification on the valve in accordance with DIN 19 such as DN PN manufacturer s logos of the Neotecha AG company The identification of the valve bod...

Page 4: ... the hand lever can be provided with limit switches which indicate open or closed For installation in exposed places shaft extensions in various lengths are available for all sizes 6 6 Bolted joints in the pipeline All flange bolts must be used even on low pressure systems The specified tightening toques for the bolts must always be adhered to 6 7 Body variants NTB and NTC ball valves have the sam...

Page 5: ... mm inches Nm 6 9 1 Recommended tightening torques for NTB NTC ball valves DIN PN 16 and JIS 10K RECOMMENDED TORQUES DN Bolts Class Torque mm inches UNC lbf ft 6 9 2 Recommended tightening torques for NTB NTC ball valves ANSI B 16 10 class 150 lbs 6 8 Step by step valve installation 1 Check that the distance between flanges matches the face to face dimension of the ball valve Before installing the...

Page 6: ...t is installed or existing protective equipment repaired 9 USE 9 1 Operation general NTB series ball valves should only be used in the fully open or fully closed position as they are not designed for flow regulation Intermediate settings can result in turbulence leading to vibrations in the pipeline system which then generates noise If the flow has to be regulated an NTC series C valve should be u...

Page 7: ...the information in accordance with the rating plate fitted on the mounting flange when ordering seals and other spare parts 14 DISPOSAL Hand in the correctly cleaned valve to the scrap material recycling plant Badly cleaned valves can cause severe burning of the hands and other parts of the body If the valve is passed on to a third party the manufacturer no longer guarantees the valve 10 SERVICING...

Page 8: ...son logo are trademarks and service marks of Emerson Electric Co All other marks are the property of their respective owners The contents of this publication are presented for informational purposes only and while every effort has been made to ensure their accuracy they are not to be construed as warranties or guarantees express or implied regarding the products or services described herein or the...

Reviews: