Figure 4-3: Externally-powered mA Output: maximum loop resistance
0
100
200
300
400
500
600
700
800
900
1000
1100
0
7.5
15.0
22.5
30.0
B
A
A. Maximum resistance (Ω)
B. External supply voltage (V)
4.2.3
Wire the Frequency Output
Wire the Frequency Output in nonhazardous installations.
Prerequisites
WARNING
Meter installation and wiring should be performed only by suitably-trained personnel
using the appropriate government and corporate safety standards.
Procedure
Wire to the appropriate output terminal and pins.
Figure 4-4: Internally-powered FO wiring
A
D
C
B
A. Frequency Output
B. Channel B
C. See
D. Counter
Installation Manual
Wiring the channels
00825-0100-1600
March 2022
Installation Manual
19