10
Keystone
OM9 - EPI2 PrOfIbus DPV1 IntErfacE
InstallatIon & MaIntenance InstructIons
fIGurE 29
fIGurE 30
fIGurE 31
• Disassemble local mechanical indicator and connect OM9 flat cable to connector
on the logic board (figure 29).
• Place the OM9 card onto the spacers and tighten the 4 screws; assemble local
mechanical indicator (figure 30).
• Connect the 8-pins connector to connector J3 on OM9 (Figure 31)
important
Please note that all the connectors provided with the base actuator and all optional cards are different
from each other (in terms of design and number of pins). In no way is it possible to make a wrong
connection.
• The OM9 card is now connected.
• Replace the actuator cover and fix it properly.