1592012000 XF330M XF331M XF332M  GB REL1.0 31.08.2015 

XF330M XF331M XF332M 

9/12 

Ab

  = 

absolute  temperature

:  High  and  low  ceiling 

temperature  alarms  are  established  by  the  AL1  and 
AU1 parameters. 

 

AL1 Low temperature alarm for the ceiling  

AC1

 = 

rE

:  0 ÷ 120°C 

AC1

 = 

Ab

: Down scale ÷ Au1 

when this temperature is reached and after the 

dA1

 

delay time, the LA alarm is enabled,. 

AU1 High temperature alarm for the bottom:

  

 

AC1= rE

: 0 

 

120°C  

 

AC1= Ab:

 AL1 

  End Scale 

 

when this temperature is reached and after the 

dA1

 

delay time the HA alarm is enabled. 

dA1  Temperature  alarm  delay  for  the  ceiling 

temperature:

 (0÷120 min) time interval between the 

detection  of  a  ceiling  temperature  alarm  condition 
and the corresponding alarm signalling. 

HA1  Differential  for  temperature  alarm  returns: 

(1÷15°C)  differential  for  the  re-entry  of  the  alarm 
signalling.  

AC2 Bottom temperature alarm configuration 

rE

  = 

related  to  bottom  Set  Point 

High  and  Low 

temperature  alarms  are  signalled  when  the 
temperature  exceeds  the  following  values: 
“SET+AU2” and “SET+AL2”.

 

Ab

  = 

absolute  temperature

:  High  and  low  ceiling 

temperature  alarms  are  established  by  the  AL2  and 
AU2 parameters. 

AL2 Low temperature alarm for the bottom  

AC2

 = 

rE

:  0 ÷ 120°C 

AC2

 = 

Ab

: Down scale ÷ Au2 

when this temperature is reached and after the 

dA2

 

delay time, the LA alarm is enabled,. 

AU2 High temperature alarm for the bottom:

  

 

AC2 = rE

: 0 

 

120°C  

 

AC2 = Ab:

 AL2 

  End Scale 

 

when this temperature is reached and after the 

dA2

 

delay time the HA alarm is enabled. 

dA2  Temperature  alarm  delay  for  the  bottom 

temperature:

 (0÷120 min) time interval between the 

detection  of  a  bottom  temperature  alarm  condition 
and the corresponding alarm signalling. 

HA2  Temperature  alarm  differential: 

(1÷15°C) 

differential for the re-entry of the alarm signalling.  

tcE  Energy Saving cycle time (

1 ÷ 999 sec) it sets the 

Energy Saving cycle duration. 

dcy  Switching  on  percentage  for  the  ceiling  output 

during the Energy Saving cycle

 (0 ÷ 100 %)  

i1P  Digital  input  polarity  to  enabling  steam  injection 

(only for XF331M) 

(oP÷CL) 

oP = 

the steam injection 

is enabled if voltage is not present; 

CL = 

the steam 

injection is enabled if voltage is present; 

Ptb  Parameter  table  code:

  (read  only)  it  shows  the 

original code of the map. 

rEL  Release  software:

  (read  only)  Software  version  of 

the microprocessor. 

 

14.

 

Use of the programming key “Hot 

Key” 

The XF units can UPLOAD or DOWNLOAD the parameter 
list from its own E2 internal memory to the 

“Hot Key” 

and 

vice-versa. 

14.1

 

DOWNLOAD (From the “Hot Key” to the 

instrument) 

1.

 

Turn OFF the instrument by means of the ON/OFF 
key,  insert  the 

“Hot  Key” 

and  then  turn  the 

instrument ON. 

2.

 

Automatically the parameter list of the 

“Hot Key”

 is 

downloaded  into  the  controller  memory,  the  “

doL

” 

message  is  blinking.  After  10  seconds  the 
instrument  will  restart  working  with  the  new 
parameters. 

At  the  end  of  the  data  transfer  phase  the  instrument 
displays the following messages: 

End

  “  for  right  programming.  The  instrument  starts 

regularly with the new programming. 

Err

” for failed programming. In this case turn the unit off 

and then on if you want to restart the download again or 
remove the “

Hot key

” to abort the operation. 

 

14.2

 

UPLOAD (From the instrument to the “Hot 

key”) 

1.

 

When the unit  is ON, insert the “

Hot key

”  

2.

 

Push the 

UP

 

key of the Ceiling display; the  

"uPL" 

message appears. 

At  the  end  of  the  data  transfer  phase  the  instrument 
displays the following messages: 

End

 “ for right programming. 

Err

” for failed programming. In this case push “

UP

” key if 

you want to restart the programming again or remove the 
not programmed “

Hot key

”. 

15.

 

Mounting & installation 

The  instruments  are  suitable  only  for  internal  use.  They 
are panel mounted, hole dims 69x135 mm, and fixed with 
the supplied clips.  
The  ambient  operating  temperature  range  is  between 
0÷60°C.  
Avoid locations subject to heavy vibration, corrosive gases 
or excessive dirt. The same applies to the probes. Ensure 
ventilation around the instrument.  
 

Summary of Contents for Dixell XF330M

Page 1: ...Controllers for electric ovens XF330M XF331M XF332M ...

Page 2: ... the right to change the composition of its products even without notice ensuring the same and unchanged functionality 1 2 Safety Precautions Check the supply voltage is correct before connecting the instrument Do not expose to water or moisture use the controller only within the operating limits avoiding sudden temperature changes with high atmospheric humidity to prevent formation of condensatio...

Page 3: ...rt of the oven DAILY REPETITION to set the current day and to select the days for the automatic start of the oven PRG to set and select the pre programmed cooking cycles EXTRACTOR Switch on and off the steam extractor Not present in the XF331M STEAM ENABLING Switch on and off the steam generator relay Not present in the XF332M STEAM INJECTION Enables the steam injection ENERGY SAVING enables the e...

Page 4: ...the SET key or wait 10s to exit and confirm the setting NOTE To change quickly the temperatures hold pressed the UP and DOWN keys 5 2 How to set and modify the cooking time 1 Push the TIMER key 2 The TIME display will show the cooking time hour and minutes The LED of the key will be turned on 3 To change the value push UP and DOWN buttons on the right of the display 4 To memorise the new time push...

Page 5: ...en is on push and release the DAILY REPETITION key 2 The TIME display shows the dAy1 Monday message If the led of the DAILY REPETITION key is on it means that the automating starting is enabled for Monday 3 To enabled or disable the automatic starting push and release the DAILY REPETITION key The led is turned on and off respectively 4 Use the UP key to see the other day of the week day2 Thursday ...

Page 6: ...program After selecting a programme the PRG LED is on push the START key to start the cooking cycle 8 Steam 8 1 Steam generator Not present in XF332M By pushing the STEAM key the relay of the steam generator is switched The status of the Generator is monitored by the led if the led is ON the generator is working if the LED is off the generator is off XF331M the XF331M is provided with a digital in...

Page 7: ... of the extractor is monitored by the led if the led is ON the extractor is working if the LED is off the extractor is off 9 2 Automatic activation of the steam extractor before the end of a cooking cycle The extractor can be activated automatically some minutes before the end of a cooking cycle To set the time act as follow 1 Push the EXTRACTOR key till the time display will show the activation t...

Page 8: ...inimum set point limit for ceiling Down scale set1 Sets the minimum acceptable value for the set point of ceiling US1 Maximum set point limit for ceiling SET1 End scale Set the maximum acceptable value for set point of ceiling Hy2 Bottom differential 99 99 C Intervention differential for the bottom set point Output is activated when the bottom temperature is less than Set Point Hy2 LS2 Minimum set...

Page 9: ...ching on percentage for the ceiling output during the Energy Saving cycle 0 100 i1P Digital input polarity to enabling steam injection only for XF331M oP CL oP the steam injection is enabled if voltage is not present CL the steam injection is enabled if voltage is present Ptb Parameter table code read only it shows the original code of the map rEL Release software read only Software version of the...

Page 10: ...ature alarms HA and LA automatically stop as soon as the temperature returns to normal values 17 3 Probe failure alarms PF Probe alarm PF starts some seconds after the fault in the related probe it automatically stop some seconds after the probe restarts normal operation Check connections before replacing the probe 17 4 Real time clock alarm rtc The rtc alarm is signalled when an error happened du...

Page 11: ... 8A 250Vac 12A 250Vac 8A 250Vac 8A 250Vac 8A 250Vac C 8A 250Vac 22 230Vac input for injection enabling L N 6 2 1 12 9 3 13 8 5 10 11 14 17 18 16 Light C C C Fan XF332M 8A 250Vac 12A 250Vac 8A 250Vac 8A 250Vac 8A 250Vac C 8A 250Vac 20 Cooking programs pre set values Ceiling set Bottom set Time Program 1 100 100 30 min Program 2 100 100 30 min Program 3 100 100 30 min Program 4 100 100 30 min Progra...

Page 12: ...10 Pr1 10 Pr1 Tco Steam injection time 0 60 min 3 Pr1 3 Pr1 3 Pr1 HSi Maximum time for steam injection 0 60 sec 10 Pr1 10 Pr1 10 Pr1 TES Automatic activation of the steam extractor before the end of cooking 0 99 min 0 Pr1 0 Pr1 tFS Fan restarting delay after steam injection 0 99 min 0 Pr1 Ac1 Ceiling temperature alarm configuration Ab absolute rE relative Ab Pr2 Ab Pr2 Ab Pr2 AL1 Low temperature a...

Reviews: