background image

Type 99

9

disk or O-ring seat are referenced in Figure 9, part key 

numbers unique to the 1000 psig (69,0 bar) maximum 

inlet regulator are referenced in Figure 11, and part  

key numbers for a Type 61HP (extra high pressure) 

pilot is referenced in Figure 12.
  1.  Access to all internal actuator parts can be gained 

 

      without removing the main valve body from the  

      line. Disconnect the loading tubing from the 

 

      upper casing.

CaUTIOn

If the regulator has an indicator 

assembly, perform the following step 

carefully to avoid bending the travel 

indicator stem (key 103, Figure 6).

note

The O-rings and gaskets (keys 111 and 

108, Figure 6) in the indicator assembly 

are static seals and need not be 

disturbed, unless they are leaking.

  2.  Remove the four cap screws (key 58, Figure 9) and 

 

       lift off the spring case (key 1, Figure 9).  Remove 

 

       the travel indicator stem, if any, by unscrewing the     

       indicator stem adapter (key 101, Figure 6).
  3.  Remove the main spring seat (key 2, Figure 9)   

 

       and main spring (key 3, Figure 9).
  4.  Remove the 12 cap screws (key 12, Figure 9) 

 

       and hex nuts (key 13, Figure 9), and lift off the  

       upper casing.
  5.  Remove the diaphragm (key 11, Figure 9) and 

 

       diaphragm plate (key 10, Figure 9) by tipping it so  

       that the lever (key 9, Figure 9) slips out of the  

       pusher post (key 8, Figure 9).
  6.  Separate the diaphragm and diaphragm plate by 

 

       unscrewing the diaphragm rod (key 4, Figure 9)   

       from the pusher post.  Inspect the diaphragm 

       (key 11, Figure 9) and pusher post gasket (key 7,  

       Figure 9).  Either part must be replaced if it is 

 

       damaged or no longer pliable.
  7.  If the unit has a stem seal O-ring (key 64, 

      Figure 7 or 11), this O-ring may be replaced by  

       removing the retaining ring or cotter pin (key 28,  

       Figure 9) and disconnecting the lever from the  

       valve carrier (key 26, Figure 9 or 11), removing  

       the union nut  (key 14, Figure 9 or 11),  

       disconnecting the pilot supply tubing (key 24,  

       Figure 9 or 11), and sliding the lower casing  

       (key 29, Figure 9) away from the valve body  

       (key 17, Figure 9), with a disk or O-ring seat, the  

       valve carrier must be pulled out of the lower  

       casing to gain access to the O-ring.  Another 

 

       O-ring, held captive by the pressed-in bushing, is  

       part of the lower casing assembly on a stem seal  

       unit and normally does not require replacement.
  8.  If clogging is suspected in the upstream regulator 

 

       passages, disconnect the pilot supply tubing  

       (key 24, Figure 9 or 11), remove the filter assembly 

 

       (key 75, Figure 9), and blow through it to check  

       for filter clogging.  If necessary, to clean or replace 

 

       filter parts in a standard P590 Series filter 

 

       assembly, remove the following as shown in  

       Figure 10: filter body (key 1), machine screw 

 

       (key 4), spring washer (key 6), gasket (key 7),  

       washer (key 5), and filter element (key 2).  Upon 

 

       reassembly, one of the flat washers must go 

 

       between the filter element and filter head (key 3) 

 

       and the other must go between the filter element 

 

       and gasket.
  9.  If the lower casing was removed, install a new body 

 

       gasket (key 16, Figure 9) and, with a disk or O-ring  

       seat, slide the valve carrier into the casing.  Then 

 

       slide the entire assembly into the valve body (disk  

       or O-ring seat) and secure with the union nut.  

 

       Secure the lever to the valve carrier with the  

       retaining ring or cotter pin.
  10.  Loosely reassemble the diaphragm and 

 

        diaphragm plate so that the bolt holes and  

         loading connection hole in the diaphragm can  

         be properly aligned with the corresponding  

         holes in the casing when the lever is fitted 

 

         properly into the pusher post.  When this 

 

         orientation is made, install the collar (key 6,  

         Figure 9) and tighten the diaphragm rod into the  

         pusher post (key 8, Figure 9).
  11.  In order for the regulator to operate properly, the 

 

         assembled collar, diaphragm, diaphragm plate,  

         pusher post, and diaphragm rod must be  

         mounted on the ball of the lever so that the  

         pusher post (key 8, Figure 9) orientation is as  

         shown in Figure 9.
  12.  Install the upper casing and secure it to the 

 

         lower casing with the twelve cap screws torque  

         580 to 920 inch-pounds (65,5 to 104 N•m) and hex  

         nuts.  Put lower casing back on body and install  

         union nut.

Summary of Contents for 99

Page 1: ... H110 pop relief valve The pilot supply regulator reduces inlet pressure to a usable 200 psig 13 8 bar for the extra high pressure pilot This regulator comes standard with O ring seals on the guide bushing and valve carrier key 26 Figure 7 to keep main valve body outlet pressure from interfering with outlet pressure in the lower casing assembly key 29 Figure 9 Specifications Warning Since a pilot ...

Page 2: ...ber Color Code Wire Diameter Inches cm Free Length Inches cm 61L 400 27 6 2 to 4 inches w c 3 to 12 inches w c 0 25 to 2 psig 1 to 5 psig 2 to 10 psig 5 to 15 psig 10 to 20 psig 5 to 10 mbar 7 to 30 mbar 0 02 to 0 14 bar 0 07 to 0 34 bar 0 14 to 0 69 bar 0 34 to 1 03 bar 0 69 to 1 38 bar 1B558527052 1C680627222 1B886327022 1J857827022 1B886427022 1J857927142 1B886527022 Orange Unpainted Red Yellow...

Page 3: ...he main diaphragm E through the downstream control line Figure 2 Schematic of Type 99 Regulator with Type 61L Low Pressure Pilot In operation assume the outlet pressure is less than the setting of pilot control spring A The top side of pilot diaphragm assembly F will have a lower pressure than the setting of spring A Spring A forces the diaphragm head assembly upward opening the relay or inlet ori...

Page 4: ...his diaphragm opposes the force of the pilot control spring A Monitoring Systems Monitoring regulators serve as overpressure protection devices to limit system pressure in the event of open failure of a working regulator feeding the system Two methods of using Type 99 regulators in monitoring systems are as follows Working Monitor On a working monitor installation Figure 4 the control line of the ...

Page 5: ...must have an O ring seal on the valve carrier assembly This seals off the leak path that otherwise would let line pressure ahead of the working regulator inlet try to close the wide open monitoring regulator Figure 4 Working Monitor Installation Figure 5 Typical Wide Open Monitor Installations Flexible arrangement that permits wide open monitor to be either upstream or downstream Flexible arrangem...

Page 6: ...r should be inspected for damage periodically and after any overpressure condition Warning The 1000 psig 69 0 bar maximum inlet regulator must not be used on hazardous gas service unless the Type H110 relief valve can be vented into a safe area If vented gas can accumulate and become a hazard in enclosed conditions such as in a pit underground or indoors the relief valve must be repiped to carry t...

Page 7: ...g key 24 Figure 9 or 11 However as long as the 1 4 inch NPT tapping in the main valve body is plugged this tubing may be disconnected from both the main valve and filter assembly key 75 Figure 9 in order to install a pilot supply line from a desired remote location into the filter If the maximum pilot inlet pressure will be exceeded by main valve pressure install a separate reducing regulator if n...

Page 8: ...e 3 Slowly open the downstream block valve 4 Slowly close the bypass valve if any 5 Check all connections for leaks The only adjustment on the regulator is the reduced pressure setting affected by the pilot control spring key 43 Figure 9 or 11 Remove the closing cap assembly key 46 Figure 9 and turn the adjusting screw key 45 Figure 9 or 11 Turning the adjusting screw clockwise into the spring cas...

Page 9: ...9 away from the valve body key 17 Figure 9 with a disk or O ring seat the valve carrier must be pulled out of the lower casing to gain access to the O ring Another O ring held captive by the pressed in bushing is part of the lower casing assembly on a stem seal unit and normally does not require replacement 8 If clogging is suspected in the upstream regulator passages disconnect the pilot supply t...

Page 10: ...d in the body Note Before putting the relay spring case over the diaphragm make certain the yoke is square with respect to the prong in the relay body The yoke can bind on the prong if it is not square 7 Use care in reassembly to be sure the edges of the diaphragms slip properly into the recess on the lower casing and relay valve body With the pilot in place check to see if it can be rocked If it ...

Page 11: ...anging from a low to high pressure pilot or vice versa everything below the lower pilot diaphragm key 40 Figure 9 except the cap screws and the hex nut keys 47 and 13 Figure 9 will need to be replaced Actuator and main valve parts may remain unchanged unless a change in service conditions requires a change in seat construction main spring or main spring seat See the Parts List sections for obtaini...

Page 12: ...orifice R99HPX00012 1 1 8 inch 28 6 mm orifice R99HPX00022 Travel Indicator Assembly Figure 6 Key Description Part Number Complete Assembly includes individual parts listed below 20A7146X0C2 1 Spring Case Cast iron 2L296219012 101 Indicator Stem Adaptor Aluminum 1R395909012 102 Indicator Cap Aluminum 1L290809012 103 Indicator Stem Aluminum 1L296509022 104 Disk Nut Plastic 1F730506992 105 Machine S...

Page 13: ... 1C2546X0012 2 inch DN 50 CL125 FF flanged Cast iron 2D986519012 2 inch DN 50 CL250 RF flanged Cast iron 2D986619012 Key Description Part Number 17 Valve Body continued 2 inch DN 50 CL150 RF flanged Steel 2E275622012 2 inch DN 50 CL300 RF flanged Steel 2E275722012 18 Holder for Type 99 regulator Disk seat Brass 1B884314012 316 Stainless steel 1B884335072 O ring Seat 7 8 inch 22 2 mm orifice Brass ...

Page 14: ...omplete Regulator showing Type 61L pilot and disk seat 1 4 inch 6 35 mm vent shown 90 counterclockwise from normal pts pts lub AS pts pts control line tap other tap 180 opposite pts AS pts AS AS AS Apply ANti seize compound pts Apply pipe thread sealant LUB Apply Lubricant o ring set detail DJ6642 DJ6642_B ...

Page 15: ...Type 99 15 Figure 9 Type 99 Regulator with Type 61L Low or 61H High Pressure Pilot continued Pilot Relay and cover Assembly High Pressure Pilot Parts C0289 1C 30A6800 ...

Page 16: ...d 1B8850X0012 Cotter Pin for Stainless steel trim 316 Stainless steel 2 required 1A866537022 Key Description Part Number 29 Lower Casing Cast iron Standard 4B983719012 For use with optional protector spring washer and machine screw keys 61 62 and 63 2N379419012 Lower Casing Assembly for use with O ring stem seal Cast iron with SST guide bushing Complete with Nitrile NBR O ring 2R7230000A2 Complete...

Page 17: ... Key Description Part Number 13 Hex Nut Plated steel 13 required 1A340324122 23 Elbow 2 required Brass 15A6002X292 316 Stainless steel 15A6002X612 24 Pilot Supply Tubing disk or O ring main valve seat Copper 1D8793000A2 Copper for oxygen service 0500201701W 316 Stainless steel 0500213809W 30 Upper Relay Diaphragm Nitrile NBR 1B885202052 Fluorocarbon FKM 1N162802332 31 Upper Relay Diaphragm Plate P...

Page 18: ...carbon FKM 1B8868X0012 303 Stainless steel Fluorocarbon FKM 1B8868X0022 49 Bleed Valve Spring Stainless steel For use with low pressure pilot with relay orifice 1D373735032 or bleed valve 1H951635132 1E643637022 For use with all low and high pressure pilots Inlet pressure up to 250 psig 17 2 bar 1C911537022 Inlet pressure over 250 psig 17 2 bar 1N859137022 50 Bleed Valve Stainless steel For use wi...

Page 19: ...mber 34 Connector 3 required For use with all standard regulators Brass 1D692214012 316 Stainless steel 15A6002X602 For use with 1000 psig 69 0 bar maximum inlet regulator Steel 15A6002XW22 35 Cap Screw Plated steel 6 required 1A930424052 36 Elbow Plated steel 1B860828992 37 Yoke Cap 416 Stainless steel 13A9837X012 38 Inlet Orifice 303 Stainless steel 1D318135032 39 Pilot Body Cast iron 33A9845X01...

Page 20: ...regulators Type 61HP Extra High Pressure Pilot Figure 12 continued Key Description Part Number 45 Adjusting Screw Plated carbon steel Standard 1C216032992 47 Cap Screw Plated steel 8 required 1B787724052 49 Relief Valve Spring 316 Stainless steel 1C374037022 50 Relief Valve Plug 316 Stainless steel 1K377535162 52 Bleed Orifice Brass 1B329014012 53 Loading Tubing For use with all standard regulator...