View pH or ORP* / Cl / Temp
The instrument can only display a few items on the main screen, including the 3 main parameters: pH, chlorine
dioxide and temperature. Set YES or NO to enable or disable the display of these items.
Feeding
The distribution of the dioxide from the storage tank it’s launched by using an internal relay. Field not editable.
Reset
To restore the instrument to the factory settings, select this item and confirm with "YES". The instrument will
restart with the initial configuration values . Note: this operation also deletes and restores the two PASSCODEs.
Once restarted you must configure the instrument.
Standby
This function allows the stop all instrument activities (LOCK ALL) or the dosing activity only (DOSING ONLY)
when there is a change in the contact. Configurable options are: contact type NO - N.C. or disabled. Choose
LOCK ALL for the complete stop of instrument or DOSING ONLY to stop dosing activity only. The contact is
located on module MDCL-CH1 (pin 1 and GND).
CC/S
This option set CC/S value for storage pump and can be configured from 0,01 to 9,99 CC/S. Change this value
only if system is working at different values than 5bar.
RESERVE
This option set production cycles countdown starting from last low level warning (for Hcl and NaClO
2
pumps).
Accetted values are within 0 (disabled) and 200.
PROD.
This option allows you to limit dioxide production until the storage tank is not completely empty. Select “LEVEL
CONTROL.” To enable this option. To disable select “CONT.”
*as specified during order