Chapter 1 Introduction
1-9
NOTE:
Hot-swapping the PSU also removes the cooling module at the lower
slot.
As shown in
Figure 1-9
, each PSU comes with a power socket and a power
switch to turn the subsystem on and off. Two (2) embedded cooling fans
provide sufficient airflow. A single LED indicates the PSU status. When a
power supply failure occurs, the red LED lights come on. A rejection handle
at the rear of the PSU is especially designed to help properly install or
remove the module.
A screw hole on the ejection handle helps secure the PSU to the chassis.
Figure 1-9: PSU Module
Please refer to
Appendix B
for the technical information of the PSUs.
1.2.7 Cooling Modules
Two cooling modules are implemented within the rear sections of PSU
modules. (see
Figure 1-10
.) The cooling fans operate at two (2) fan speed
levels. When the subsystem operates normally, the cooling fans operate at
the lower speed. If a major component fails or when one of the temperature
thresholds is violated, the cooling fans automatically raise its rotation speed.
More technical information can be found in
Appendix B
.