2.6 BBU Installation
2.6.1 BBU Module Installation Overview
The BBU module is an optional item that can sustain cache memory in the event of a
power failure or in the unlikely event of failing both PSUs. A BBU is highly
recommended. The optional BBU provides additional data security and helps
minimize the loss of data during power shutdowns.
The BBU module is inserted into a module slot on the controller module. The BBU
module is secured with two (2) retention screws. When shipped, the BBU module
slot is covered with a dummy plate that must first be removed.
2.6.2 BBU Warnings and Precautions
Do not use nor leave the BBU near a heat source. Heat can melt the
insulation and damage other safety features of battery cells, possibly
leading it to acid leak and result in flames or explosion.
Do not immerse the BBU in water nor allow it to get wet. Its protective
features can be damaged. Abnormal chemical reactions may occur,
possibly causing functional defects, acid leak, and other hazardous
results.
Do not disassemble or modify the BBU. If disassembled, the BBU
could leak acid, overheat, emit smoke, burst and/or ignite.
Do not pierce the BBU with a sharp object, strike it with a hammer, step
on it, or throw it. These actions could damage or deform it, internal
short-circuiting can occur, possibly causing functional defects, acid
leak, and other hazardous results.
If the BBU leaks, gives off a bad odor, generates heat, becomes
discolored or deformed, or in any way appears abnormal during use,
recharging or storage, immediately remove it from the subsystem and
stop using it. If this is discovered when you first use the BBU, return it
to Infortrend or your system vendor.
2.6.3 Installation
Procedure
To install a BBU into the controller module, please follow these steps:
Step
1.
Prior to installing the BBU module, power off the
subsystem or restart the subsystem after installation. For
power off procedures, please refer to
Section 4.4
.
Step 2.
Use a screwdriver to
loosen the two (2) retention screws
located on both sides of the dummy plate.
(See
Figure 2-
2
)
Summary of Contents for SecurStor 16i
Page 11: ...SecurStor 16i Installation and Hardware Reference Manual xi This page intentionally left blank...
Page 12: ......
Page 25: ...Chapter 1 Introduction 1 13 This page intentionally left blank...
Page 26: ......
Page 36: ......
Page 46: ......
Page 76: ......
Page 91: ...Appendix C Uninterruptible Power Supply C 5 This page is intentionally left blank...