Many methods have been tried, but always with associated problems. Historically, chlorination has 

been used as the major chemical control of bio-fouling. Government regulations have placed increasingly 

severe limitations on chlorine concentrations and duration, to the extent that intermittent chlorination at 

the dosages permitted is not always an effective deterrent to the settlement and growth of marine 

organisms. Chemical methods produce severe corrosion problems and can cost more to operate. Methods 

must be capable of controlling primary fouling organisms, have low solubility, reduce pitting, be 

compatible with existing equipment, and present no environmental hazards. 

 

MARELCO™ 

meets these requirements by slowly dissolving special alloyed anodes into electrolytic 

products (less than 10 mg/litre) which creates a environment hostile to primary forms of marine fouling 

while at the same time reducing corrosion. 

 

Impressed direct constant current is applied to the anodes, generating aluminum hydroxide from the 

trap corrosion anode and copper ions into solution from the marine growth anode. Aluminum hydroxide 

suspends the released copper, and being highly gelatinous spreads out into the slower moving areas of 

the sea chests, where marine growth larvae are most likely to settle. Treatment is concentrated at the 

inlet areas before water enters the various services. Sea water moving past the anodes acts as the mixing 

agent, and the motive force to carry the suspension throughout the system. 

 

Not only does the trap corrosion anode produce the colloidal suspension, it also actuates a corrosion 

cell that protects the cathode from adverse reaction to copper. This dual system guarantees the 

elimination of marine growth, reduction of corrosion, elimination of pitting, and is environmentally safe. 

 

(ii)

 

Corrosion Protection

 

Total corrosion prevention is rarely achieved, although it can be in specific instances. The concept of 

corrosion control includes a broad spectrum of techniques ranging from acceptance of a finite life to some 

quantitative diminution of the rate of attack, for example, in inhibited cooling water systems. 

 

MARELCO™ 

inhibits corrosion in water cooling systems by an electrochemical and barrier film 

technique. The system produces a tiny, corrosion resistant and sacrificial film between the metal and its 

environment. The trap corrosion anode creates ionic products which form a gelatinous alkaline coating 

on the pipe surface or structure (the cathode) inhibiting corrosion up to 85% in a complete corrosion 

protection system with the installation of treatment tanks. In practice, the pipe looks as if its internal 

surface is coated. 

Summary of Contents for NOXX MARELCO

Page 1: ...0 P a g e...

Page 2: ...Anti fouling System Installation Operational Manual Vessel Name Company EMCS INDRUSTRIES LTD Reference Number Vessel Superintendent Project Manager Revision Date Description Signature 1 MARELCO ANODE...

Page 3: ...ROL PANEL 9 i Panel Exterior 9 ii Panel Interior 11 Meter Card 12 Anode Card 13 Meter Card Open Circuit Fault Level Mode High 14 Meter Card Short Circuit Fault Level Mode Low 16 2 SAFETY CAPS 18 3 ANO...

Page 4: ...include a reduced fuel consumption b increased plant and equipment efficiency c reduced costs for cleaning sea chests gratings heat exchangers condensers pipes valves etc d increased life span of pip...

Page 5: ...pper and being highly gelatinous spreads out into the slower moving areas of the sea chests where marine growth larvae are most likely to settle Treatment is concentrated at the inlet areas before wat...

Page 6: ...e various services Additional anodes may be located within the services being protected Components that may receive protection include gratings sea chests sea wells holding tanks thrusters piping scoo...

Page 7: ...marelco emcsindustries com www emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 6 MARELCO TREATMENT TANKS Wiring for anodes to Control Panels is identical...

Page 8: ...Tel 250 656 5366 Fax 250 656 5344 Contact marelco emcsindustries com www emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 7 MARELCO ANODE CAGE...

Page 9: ...cable and power 1 CONTROL PANEL The MARELCO constant current control unit is a high quality steel dust splash proof cabinet which incorporates all solid state circuitry and heavy duty components produ...

Page 10: ...250 656 5344 Contact marelco emcsindustries com www emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 9 READINGS SHEET VESSEL _ Anode Ref Type Location Amp...

Page 11: ...een light indicates ON when the unit is energized The green light will run continuously indicating that everything is functioning properly with the power supply The red light indicator should be OFF a...

Page 12: ...mcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 11 METER CARD Each control panel contains a meter card that indicates voltage and amperage to each anode Th...

Page 13: ...344 Contact marelco emcsindustries com www emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 12 ANODE CARDS Identical anode cards incorporate the following...

Page 14: ...e is higher than normal This could be caused by broken anode wire expired anode disconnected anode blown fuse on this anode card fresh water or no water in anode locations TO ADJUST THE OPEN CIRCUIT F...

Page 15: ...Tel 250 656 5366 Fax 250 656 5344 Contact marelco emcsindustries com www emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 14...

Page 16: ...e activated when the following occurs broken or damaged wire shorting to the cathode steel anode not properly insulated from the cathode steel TO AJUST THE SHORT CIRCUIT FAULTLEVEL Select the anode ca...

Page 17: ...emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 16 RED INDICATES CUSTOMER RESPONSIBILITY YELLOW INDICATES EMCS TECHNICIAN COMMISSIONING RESPONSIBILITY NO...

Page 18: ...ly made for your vessel system are made available according to the application The below is an example of a Control Panel designed to avoid the use of Spare Anodes being used before it necessary SEE F...

Page 19: ...ds i MG Anodes The MG anode is constructed of specially alloyed extruded material principally copper plus various alloys It is always employed in conjunction with the TRAP fC anode It reacts with sea...

Page 20: ...Tel 250 656 5366 Fax 250 656 5344 Contact marelco emcsindustries com www emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 19...

Page 21: ...LE Cable from the junction box to the safety cap shall be supplied by the owner or shipyard and shall be 12 or 3 3 mm single conductor marine cable or 14 or 2 0 mm double conductor marine cable or loc...

Page 22: ...chest for the system to be effective All sea chests must be adequately vented 6 MARINE INSTALLATION REQUIREMENTS i Sea Chests Anodes mounted in the sea chests treat raw sea water before it enters the...

Page 23: ...he panel are not obstructed The control panel should be opened so that the back section Ounction section isexposed 2 CABLE a Run AC power from the main supply to the control panel terminals located on...

Page 24: ...lace anode on mounting ring and gasket and secure accordingly Use a torque setting of 100 foot pound e Secure anode cable in anode gland and connect the anode lead terminal to the junction box cable t...

Page 25: ...d and fuses are secured in holders orracks 4 Switch on the primary power supply 5 Check that the green operational light is on 6 Check each anode to ensure that each anode card registers a current amp...

Page 26: ...n on panel power Make sure anode is insulated from deck 3 Take DC volt meter to anode location 4 Turn meter on 5 Put ground probe to ground i e cathode NB Make sure of proper contact i e no paint or o...

Page 27: ...similar meter reading variations may be observed when operating to ice conditions Sea water resistivity will vary according to the amount of fresh water present MARELCO will monitor itself DO NOT TRY...

Page 28: ...mcsindustries com www emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 27 VARIOUS ANODE INSTALLATION METHODS Strainers various layouts safety caps are weld...

Page 29: ...ies com www emcsindustries com EMCS INDUSTRIES LTD Unit 5 10114 McDonald Park Rd North Saanich BC V8L 5X8 28 Bent anode special request only Crossovers or Piping Systems various layouts safety caps ar...

Page 30: ...ONGLY RECOMMENDED THAT FOR BEST PERFORMANCE ALL MARELCO ANODES ARE MANAGED AND RUN BY THE MARELCO LIBERATOR CONTROL PANEL ALL ANODE INSTALLATIONS MUST BE SUPERVISED BY EMCS INDUSTRIES CERTIFIED TECHNI...