22
SECTION C.
INSTALLATION
The MARELCO™ System supplied by EMCS Industries Ltd. will consist of the following parts:
1.
Control Panel c/w Junction Box (if applicable)
2.
Anodes
3.
Safety Caps
The owner, general contractor or shipyard will be responsible for the supply of:
1.
Cable
2.
Cable Clamps
3.
Cable Terminals
4.
Terminal Nuts and Bolts
5.
Panel Mounting Brackets and Bolts.
INSTALLATION METHOD
(1)
CONTROL PANEL
(a)
Mount panel in the control room or on the bulkhead in the engine room.
(b)
Care must be taken to ensure that the ventilation slots in the back of the panel are not obstructed.
The control panel should be opened so that the back section Ounction section) is exposed.
(2)
CABLE
(a)
Run AC power from the main supply to the control panel terminals located on back panel of the
controller. (Refer to drawings.)
(b)
Wire two conductor #14 AWG or 2.0 mm conductor from the seachests to the control panel
grounds.
(c)
Run a cable from the control panel anode terminal blocks to each safety cap, taking care that
the anode number matches the number on the terminal block.
(d)
Secure cables to the control panel bottom with a cable clamp.
(e)
Install cable from the control panel anode terminals into the side of the safety cap using a 13
mm brass watertight gland. At least 150 mm of cable must be left inside the safety cap. To the
end of the cable fasten a terminal with a 5 mm hole.
(f)
Run ground cable from the control panel ground terminals to each group of anode locations.
(Refer to drawings.)