POWER
Connect panel to the main AC supply. The installation is now complete, and the system is ready for
calibration (commissioning).
(5)
SYSTEM CALIBRATION
All amperage settings will be supplied with the equipment (Refer to anode amperage settings).
METHOD
1.
Ensure anodes are fully immersed in water prior to energizing equipment.
2.
Check panel for damage .
3.
Ensure that all anode circuit cards, the meter card, and fuses are secured in holders or racks.
4.
Switch on the primary power supply.
5.
Check that the green operational light is on.
6.
Check each anode to ensure that each anode card registers a current (amp) reading and a
voltage (volts) If meter does not register on all circuits take the following steps:
(i)
Check anode card fuses , meter card fuse/breaker, and AC supply fuse/breaker.
(ii)
Check ground connections.
(iii)
Check the vent lines to the tank tops, sea chests or sea bays to ensure that there is water
in them.
(iv)
Check anode lead connections in the control panel.
7.
Check that amperage settings are those supplied with the equipment. Record voltage for each
anode.
8.
If the amperage settings are incorrect, adjust amperage on each anode circuit card. Record
voltage for each anode.