Trouble Shooting Guide

The Function Display 
Panel does not come on. 

A power plug is not property 
inserted, or it is inserted into a 
faulty outlet. 

The fuse is blown. 
The fuse is not inserted properly. 

Resolution

Cause(s) 

Abnormal condition 

Resolution

Cause(s) 

Abnormal condition 

Properly insert power plug into 
a correctly functioning power 
outlet

Replace the fuse. A spare fuse 
is included in your reagent kit. 
(3A / 250V fuse) 

The Function Display Panel / 
display indicators do not 
come on even after turning 
the tap on. 

Faulty PCB 
(Printed Circuit Board)

Immediately unplug the unit 
and contact your dealer to 
arrange service.

pH test shows alkaline water
color as neutral (7) while 
acidic water color gets 
yellow (6). This is normal 
if initial pH is 6.5

Faulty or evaporated reagent: 
alkaline / acidity are always 
produced in inverse proportion. 
Therefore, showing an acidic 
color means inversely that 
alkaline water has to be 
generated from the unit. 
Lack of alkaline color can 
result from a chemical 
reaction where carbonic 
acid in water evaporates 
some test reagent elements. 

Test pH value on level 
3 or 4 water; 
replace reagent.  

Power supply is suddenly 
cut off while operating the 
unit. 

Elevated level of salt in the 
water or high TDS; extended 
operation at high pH; 
sudden flux in electrical 
current. In these cases your 
machine will shut down 
automatically to protect the 
electrodes and circuitry.  

Wait - the unit will become 
operational again after about 
one hour. Your ionizer has a 
safety mechanism built-in to 
protect the electrodes and 
circuitry. This mechanism will 
shut the ionizer down 
automatically. This mechanism 
protects the unit from overuse 
or excessive electric current. 

Low output of alkaline water 
from the unit. 

Filter is clogged. Premature 
clogging may be caused by 
sudden drop in water quality and 
an influx of sediment or other 
contaminants, which stress 
the filter. 

Low pressure in your household 
plumbing.  

The input hose is bent, kinked or 
otherwise restricted. 

Replace your filter.

Clean Pre-filter 

Ensure water supply valves are 
fully open. The water pressure 
in house may be too low.  

Straighten the bent hose. 

Strange smell from 
Alkaline water. 

Expired filter from ordinary use 
or premature clogging due to 
flux in water quality. 

Sudden flux in water quality with 
elevated level of Choline 
(not Chlorine). Elevated Choline 
levels are observed in some 
areas during summer months. 
These levels fall within safe 
drinking water standards, yet 
will cause a reaction with ionized 
water causing a unique smell. 

Replace your filter. 

Select lower pH level (1-2). 
If still present, filter replacement 
may be necessary.

Water appears milkish; 
white snow like particles 
in the bottom of your glass. 

You have high hardness (calcium 
primarily) in your water. The white 
is extracted CaCO3 (Calcium 
carbonate). After Co2 in water is 
bonded with Ca where elevated 
levels of CO3 exist in your water. 
In water where elevated levels of 
CO3 exist, what you see after 
ionization is Co2 in the water 
bonded with Ca.

This is calcium! It is not only 
harmless, but actually good for 
you. Remember the ionizer 
separates and condenses the 
alkaline minerals and this is what 
you are seeing. You can lower 
the setting (1-2) and reduce 
this effect. Typically this only 
occurs in hard water areas. 

At first no smell, but then 
smell from the alkaline 
water about one hour after. 

Your water bottle or receptacle 
is foul and needs cleaning. 
Contamination mixes with 
alkaline water when filling your 
bottle. Expired filter.

Clean your bottle or receptacle. 
Try selecting lower pH level 
(1~2). Replace your filter.

Water leakage from the 
filter cartridge housing.  

Filter not installed correctly 
into filter housing.   

Remove your filter and reinstall it 
properly following the filter 
replacement instructions. 
Increase the quantity of source 
water inflow. 

No acid water flow from the 
acidic output port. 

Acidic output hose is bent, 
kinked or otherwise restricted.

Straighten the bent hose; 
increase water flow from supply.

Poor / Irregular pH 
Production at levels 
1,2,3 and 4

Either overly hard or soft water 
(excess or lack of minerals 
in water)

Adjust the voltage output, please 
refer to page 23 in this manual

Summary of Contents for Delphi IO400U

Page 1: ......

Page 2: ...ater in this way re structures the molecules and reduces their cluster size binds extra oxygen molecules and concentrates ionized absorbable and beneficial minerals like Calcium Magnesium and Potassiu...

Page 3: ...for The pH of Purified water is neither raised nor lowered and would be the same as your tap water This water is simply cleaned of impurities by the advanced filtration system You can use it both as d...

Page 4: ...fies your selections The easy to read digital indicator gives you an approximate indication of remaining water filter life Optimum performance is ensured by always changing your filter on time In addi...

Page 5: ...may result in electric shock Ensure the power plug is firmly and properly inserted into the outlet failure to do so may result in electric shock or fire Installation Precautions Protect your ionizer...

Page 6: ...e to keep the pH reagent liquid tightly closed and out of the reach of children Acidic water is effective for washing and rinsing In order to clean the product s internal parts and in order to drink c...

Page 7: ...Speaker Volume controller Names and functions of Parts I Front Back Rear cover Connector Port Huse holder Acidic water outlet port Alkaline water outlet port Tap water inlet Main switch AC Power cord...

Page 8: ...be lit pH level indicator This numeric display will indicate which level 1 4 is selected If alkaline water is selected the number will be displayed in BLUE BLUE if acidic water is selected the number...

Page 9: ...y insert the end of the hose into the fitting Pull firmly to check to connection you should not be able to pull the hose out To release the hose from the fitting you must push the spring loaded ring p...

Page 10: ...you start flow through the ionizer next time you use the ionizer it will automatically process at Alkaline Level 2 How to Use Place the Ionizer in an appropriate place under your sink Connect the 1 4...

Page 11: ...in taste Alkaline Water Acidic Water LEVEL ALKALINE ACIDIC PURIFIED FILTER LIFE 1 Alkaline Water Acidic Water Note Acidic water is for external use only DO NOT DRINK 1 2 With the water running throug...

Page 12: ...not be displayed Fill one of the receptacles provided about 1 4 full with alkaline acidic or purified water ALKALINE WATER ACIDIC WATER PURIFIED WATER ALKALINE WATER ACIDIC WATER PURIFIED WATER How t...

Page 13: ...etting With the beep sound the default setting level 3 appears on the pH level indicator of the display panel You can select the desired setting from 0 6 To fix the setting you selected depress the FI...

Page 14: ...filter clean is critical to the proper operation of your ionizer First ensure your water supply is turned off Then remove the in line pre filter by pressing the spring loaded ring protruding from the...

Page 15: ...up to 15 seconds while Ionizer is in standby mode water not running power to machine on NOTE When filter life indicator is reset and also when machine is new no bars will be showing 27 28 Filter cover...

Page 16: ...in ceramic form so you get FIR on tap Non woven fabric filter Filters out sediment and particulate Granular Activated Carbon GAC The workhorse of the filtration media GAC is especially effective at re...

Page 17: ...eplace your filter Clean Pre filter Ensure water supply valves are fully open The water pressure in house may be too low Straighten the bent hose Strange smell from Alkaline water Expired filter from...

Page 18: ...cet where the spouts attach Use the allen wrench to loosen those screws a little to install the spouts Once you loosen the screws slide the longer of the two spouts into the top hole and tighten the a...

Reviews: