background image

15

16

Accessories 

How to Install

How to connect water faucet

How To Install

Connecting the Delphi faucet

pH test kit

Hose(1/4")

Hose(5/16")

Manual

Alkaline Water

Acidic Water

Tap Water

Tap Water

Connect Wire

Water Ionizer

DUST PRE- FILTER

Faucet

Tap water

Faucet

Circle Plate

Circle Plate

Tool

Large Alkaline 

Water Fitting

Small Acidic 

Water Fitting

1

2

Use appropriate tools to make 30mm 
diameter hole in the location where you will set 
up the faucet. Make sure the faucet location 
will allow both spouts to reach the sink.

Place the faucet in the hole properly over 
the gasket.

3

4

Insert the faucet in the hole and then screw
it with a nut to make it be fixed.

30mm

(Alkaline Water Hose)

(Acidic/Tap Water Hose)

Connector Cord

1/4” Tube(Acidic Water)

5/16” Tube(Alkaline Water)

Acidic Water

Alkaline Water

Connector Cord

All the fittings are push in style fittings. To attach the hoses to any fitting, firmly insert the end of 
the hose into the fitting. Pull firmly to check to connection - you should not be able to pull the 
hose out. To release the hose from the fitting, you must push the spring loaded ring protruding 
from the end of the fitting while pulling the hose out. 

WARNING

WARNING: incorrect installation could void your valuable warranty 

: incorrect installation could void your valuable warranty 

- professional installation is recommended.

- professional installation is recommended.

  

After the faucet is fixed, connect it to fitting
with 5/16” hose(for Alkaline) like figure 4.
Check the hose whether it is inserted properly
or not. Also, connect it with 1/4” hose(for Acidic)
like figure 4 and connect the faucet to the body
with connector cord.

Figure 1

Figure 2

Figure 3

Figure 4

Gasket

(installed under 

the Faucet)

Product Requirement : 

Product Requirement : 
Water pressure should be maintained at a constant rate, 

Water pressure should be maintained at a constant rate, 
when the water pressure is too low, water cannot flow through the unit. 

when the water pressure is too low, water cannot flow through the unit. 

Summary of Contents for Delphi IO400U

Page 1: ......

Page 2: ...ater in this way re structures the molecules and reduces their cluster size binds extra oxygen molecules and concentrates ionized absorbable and beneficial minerals like Calcium Magnesium and Potassiu...

Page 3: ...for The pH of Purified water is neither raised nor lowered and would be the same as your tap water This water is simply cleaned of impurities by the advanced filtration system You can use it both as d...

Page 4: ...fies your selections The easy to read digital indicator gives you an approximate indication of remaining water filter life Optimum performance is ensured by always changing your filter on time In addi...

Page 5: ...may result in electric shock Ensure the power plug is firmly and properly inserted into the outlet failure to do so may result in electric shock or fire Installation Precautions Protect your ionizer...

Page 6: ...e to keep the pH reagent liquid tightly closed and out of the reach of children Acidic water is effective for washing and rinsing In order to clean the product s internal parts and in order to drink c...

Page 7: ...Speaker Volume controller Names and functions of Parts I Front Back Rear cover Connector Port Huse holder Acidic water outlet port Alkaline water outlet port Tap water inlet Main switch AC Power cord...

Page 8: ...be lit pH level indicator This numeric display will indicate which level 1 4 is selected If alkaline water is selected the number will be displayed in BLUE BLUE if acidic water is selected the number...

Page 9: ...y insert the end of the hose into the fitting Pull firmly to check to connection you should not be able to pull the hose out To release the hose from the fitting you must push the spring loaded ring p...

Page 10: ...you start flow through the ionizer next time you use the ionizer it will automatically process at Alkaline Level 2 How to Use Place the Ionizer in an appropriate place under your sink Connect the 1 4...

Page 11: ...in taste Alkaline Water Acidic Water LEVEL ALKALINE ACIDIC PURIFIED FILTER LIFE 1 Alkaline Water Acidic Water Note Acidic water is for external use only DO NOT DRINK 1 2 With the water running throug...

Page 12: ...not be displayed Fill one of the receptacles provided about 1 4 full with alkaline acidic or purified water ALKALINE WATER ACIDIC WATER PURIFIED WATER ALKALINE WATER ACIDIC WATER PURIFIED WATER How t...

Page 13: ...etting With the beep sound the default setting level 3 appears on the pH level indicator of the display panel You can select the desired setting from 0 6 To fix the setting you selected depress the FI...

Page 14: ...filter clean is critical to the proper operation of your ionizer First ensure your water supply is turned off Then remove the in line pre filter by pressing the spring loaded ring protruding from the...

Page 15: ...up to 15 seconds while Ionizer is in standby mode water not running power to machine on NOTE When filter life indicator is reset and also when machine is new no bars will be showing 27 28 Filter cover...

Page 16: ...in ceramic form so you get FIR on tap Non woven fabric filter Filters out sediment and particulate Granular Activated Carbon GAC The workhorse of the filtration media GAC is especially effective at re...

Page 17: ...eplace your filter Clean Pre filter Ensure water supply valves are fully open The water pressure in house may be too low Straighten the bent hose Strange smell from Alkaline water Expired filter from...

Page 18: ...cet where the spouts attach Use the allen wrench to loosen those screws a little to install the spouts Once you loosen the screws slide the longer of the two spouts into the top hole and tighten the a...

Reviews: