Electrical power precautions

Do not attempt to repair the machine if you encounter a technical problem, first contact the 
IonWays Associate you purchased the machine from, then IonWays Technical Support if needed.               

Safety Precautions

If your ionizer becomes submerged in water, unplug the power 
cord from the wall BEFORE removing the ionizer from the water. 
Failure to do so may cause electric shock!

NEVER 

NEVER attempt to repair or service the unit yourself. 
Contact your dealer. 
Attempting to do so will void your valuable warranty!

Attempting to do so will void your valuable warranty!

Do not use your ionizer at voltages other than specified (AC 110V FOR USA). 
Use a GFI outlet. Do not plug in your ionizer where it will exceed the rating of 
outlet or electric wiring. 
Failure to do so can result in fire, injury and/or damage to yourself, 
wiring or your ionizer! 

NEVER touch the power cord or plug with wet hands 
- this may result in electric shock!

Ensure the power plug is firmly and properly inserted into the outlet 
- failure to do so may result in electric shock or fire! 

Installation Precautions

Protect your ionizer from freezing temperatures.  

Protect your ionizer from direct sunlight.  

Do not put anything heavy on top of your ionizer. 
Do not install your ionizer on an unstable or soft surface. 
Install only on a hard and level surface.

Maintenance Precautions 

Common Sense Precautions

Always unplug your ionizer when changing the fuse or cleaning your ionizer 
- failure to do so may result in electric shock.

Do not attempt to repair or service the unit yourself. Contact your dealer. 
Attempting to do so  will void your valuable warranty!

Make sure to use your ionizer only with potable water which is 
suitable for human consumption.

DO NOT use your ionizer with well water, water with extreme hardness, high sediment or 
TDS levels without first consulting your dealer.   

Do not wash your ionizer by immersion or by pouring water over the main body; 
always unplug your ionizer while cleaning the casing. 
Clean with damp sponge or cloth.

220V

Summary of Contents for Delphi IO400U

Page 1: ......

Page 2: ...ater in this way re structures the molecules and reduces their cluster size binds extra oxygen molecules and concentrates ionized absorbable and beneficial minerals like Calcium Magnesium and Potassiu...

Page 3: ...for The pH of Purified water is neither raised nor lowered and would be the same as your tap water This water is simply cleaned of impurities by the advanced filtration system You can use it both as d...

Page 4: ...fies your selections The easy to read digital indicator gives you an approximate indication of remaining water filter life Optimum performance is ensured by always changing your filter on time In addi...

Page 5: ...may result in electric shock Ensure the power plug is firmly and properly inserted into the outlet failure to do so may result in electric shock or fire Installation Precautions Protect your ionizer...

Page 6: ...e to keep the pH reagent liquid tightly closed and out of the reach of children Acidic water is effective for washing and rinsing In order to clean the product s internal parts and in order to drink c...

Page 7: ...Speaker Volume controller Names and functions of Parts I Front Back Rear cover Connector Port Huse holder Acidic water outlet port Alkaline water outlet port Tap water inlet Main switch AC Power cord...

Page 8: ...be lit pH level indicator This numeric display will indicate which level 1 4 is selected If alkaline water is selected the number will be displayed in BLUE BLUE if acidic water is selected the number...

Page 9: ...y insert the end of the hose into the fitting Pull firmly to check to connection you should not be able to pull the hose out To release the hose from the fitting you must push the spring loaded ring p...

Page 10: ...you start flow through the ionizer next time you use the ionizer it will automatically process at Alkaline Level 2 How to Use Place the Ionizer in an appropriate place under your sink Connect the 1 4...

Page 11: ...in taste Alkaline Water Acidic Water LEVEL ALKALINE ACIDIC PURIFIED FILTER LIFE 1 Alkaline Water Acidic Water Note Acidic water is for external use only DO NOT DRINK 1 2 With the water running throug...

Page 12: ...not be displayed Fill one of the receptacles provided about 1 4 full with alkaline acidic or purified water ALKALINE WATER ACIDIC WATER PURIFIED WATER ALKALINE WATER ACIDIC WATER PURIFIED WATER How t...

Page 13: ...etting With the beep sound the default setting level 3 appears on the pH level indicator of the display panel You can select the desired setting from 0 6 To fix the setting you selected depress the FI...

Page 14: ...filter clean is critical to the proper operation of your ionizer First ensure your water supply is turned off Then remove the in line pre filter by pressing the spring loaded ring protruding from the...

Page 15: ...up to 15 seconds while Ionizer is in standby mode water not running power to machine on NOTE When filter life indicator is reset and also when machine is new no bars will be showing 27 28 Filter cover...

Page 16: ...in ceramic form so you get FIR on tap Non woven fabric filter Filters out sediment and particulate Granular Activated Carbon GAC The workhorse of the filtration media GAC is especially effective at re...

Page 17: ...eplace your filter Clean Pre filter Ensure water supply valves are fully open The water pressure in house may be too low Straighten the bent hose Strange smell from Alkaline water Expired filter from...

Page 18: ...cet where the spouts attach Use the allen wrench to loosen those screws a little to install the spouts Once you loosen the screws slide the longer of the two spouts into the top hole and tighten the a...

Reviews: