How to Install
Connecting the faucet and cold water hoses to the Ionizer
Tap water
6
7
8
9
10
11
12
Connect Wire
Hose(5/16")
Hose(1/4")
Alkaline Water
Tap Water(1/4")
Acidic Water
Power Cord
DUST PRE- FILTER
Faucet
1
2
3
4
1
2
3
POWER UP YOUR IONIZER.
Turn the power button on.
Turn the power button to the "ON" position
on the back of the ionizer.
- The power button is ALWAYS left on.
- The power button is ALWAYS left on.
TURN ON THE WATER
Turn on the water by opening the water supply valve.
To select Alkaline water
Initial operation
START WATER FLOW THROUGH YOUR IONIZER
- Depress the "POWER" button on the top of your Delphi faucet to start the water flow.
- NOTE: The water may initially come out discolored (light to charcoal gray) due to carbon
particulates in the new filter.
- This is not harmful and is typical of all carbon filters. Allow the water to flow for 2-3 minutes
in the "Purified" mode and this will flush all the carbon dust.
With the water running through your Delphi faucet then:
Depress the "ALKALINE" button to select the desired setting from 1 - 4. The alkaline water will come
out from the top spout. The display panel on the front of the faucet will show a blue Alkaline indicator
and blue number corresponding to the level selected.
Note: Your ionizer will always "remember" the last setting used.
If the previous selection was Alkaline Level 2, when you start flow through the ionizer next time
you use the ionizer it will automatically process at Alkaline Level 2.
How to Use
Place the Ionizer in an appropriate place under your sink
Connect the 1/4inch Acidic Water Hose to the small fitting on the Acidic Hose extending
from the faucet to Acidic Water Outlet on the Ionizer. Pull firmly to check to connection -
you should not be able to pull the hose out.
Connect 5/16 inch Alkaline Water Hose attached to the threaded stem of the faucet to the
Alkaline Water Outlet on the ionizer. Pull firmly to check to connection - you should not be
able to pull the hose out.
Install the dust pre-filter in the middle of a length of 1/4 inch hose with the arrow pointed at
the ionizer. Connect the 1/4 inch hose with dust filter to Tap Water Inlet on the bottom of
the ionizer. Pull firmly to check to connection - you should not be able to pull the hose out.
Join the wire from the faucet to the Connect Wire. Plug the Connector Cord into the
Connector Port on the back of the ionizer.
Connect the power cord into an appropriate outlet.
Make sure the outlet you plug your Delphi into is live, and remember that many outlets under
the sink are controlled by an on/off switch.
External V
alve
Connect the external valve between the hoses.
If the water pressure is excessively high, adjust the water flow by turning
the external valve.
To get the proper pH and ORP value of ionized water, set the external valve
to allow 1.5 liters of water per minute to flow through the ionizer.
How to install the external valve
1/4" hose