background image

   

                                                                 

 

POWERJET MANUAL

 

8f749dd9-8865-44fd-baed-1b68166d2198file.doc 

                               

             

POWERJET OWNERS INSTALL & OPERATE MANUAL

 

25 

25 

 

WARRANTY & LIMITATION OF LIABILITY 

 

NOTE:  EQUIPMENT  MANUFACTURING  CORPORATION  (

EMC

)  MAKES  NO  WARRANTY  CONCERNING 

APPLICABILITY OF THE EQUIPMENT TO ANY PARTICULAR FLUID.         FINAL 

DETERMINATION 

OF 

APPROPRIATENESS OF THIS EQUIPMENT FOR ANY USAGE IS THAT OF THE CUSTOMER. 

 

EMC

    through  its  Distributor  warrants  each  new  product  sold  by  it  to  the  initial  user  to  be  free  of  defects  in  material  and 

workmanship for a period of 

One Year

 

from the date of sale of the

 

equipment.  F.O.B.  Santa Fe Springs, CA. 

 

EMC

    will  provide  a  new 

part

  or  repaired 

part

,  at  its  election,  in  place  of  any

  part

  that  is  found,  upon  inspection,  to  be 

defective in material and workmanship during the period described above. Purchaser must present proof of purchase (and 
purchase date) at the time of exercising this warranty. 

 

This warranty does not apply to failures occurring as a result of incompatibility of fluid type to material of construction, abuse, 
misuse,  negligent  repairs,  corrosion,  and  normal  wear  and  tear,  alteration  or  modifications  made  to  the  product  without 
express written consent of  

EMC

  or failure to follow the recommended operating practices and maintenance procedures as 

provided in the product’s operating and maintenance publications

 

The warranty provided herein does not apply to equipment sold hereunder but manufactured by others as they are warranted 
by their respective manufacturers directly to the user, as electric motors, engines and magnetic starters. 

 

THIS WARRANTY IS IN LIEU OF ALL OTHER  WARRANTIES, EXPRESSED OR IMPLIED, 
AND THERE ARE NO WARRANTIES, OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE.

 

 

LIMITATION OF LIABILITY 

 

The remedies of the user set forth under the provisions of warranty outlined above are exclusive and total liability of  

EMC

  or 

its Distributor with respect to this sale or the equipment and service furnished hereunder, in connection with the performance 
or  breach  thereof,  or  from  the  sale,  delivery  installation,  or  repair  or  technical  direction  covered  by  or  furnished  under  this 
sale, whether based on contract, warranty, negligence, indemnity, strict liability or otherwise shall not exceed the purchase 
price of the unit of equipment upon which such liability is based. 

 

EMC

  shall in no event be liable to the user, any successor in interest or any beneficiary or assignee relating to this sale for 

any  consequential,  incidental,  indirect,  special  or  punitive  damages  arising  out  of  this  sale  or  any  breach  thereof,  or  any 
defects  in,  or  failure  of,  or  malfunction  of  the  equipment  under  this  date  whether  based  upon  loss  of  use,  lost  profits  or 
revenue,  interest,  lost  goodwill,  work  stoppage,  impairment  of  other  goods,  loss  by  reason  of  shutdown  or  non-operation, 
increased  expenses  of  operation,  cost  of  purchase  of  replacement  power  or  claims  of  user  or  customers  of  the  user  for 
service interruption whether or not such loss or damage is based on contract, warranty, negligence, indemnity, strict liability 
or otherwise. 

 

I have read the 

EMC

 instructions and agree that they will be followed carefully. I also agree that the equipment will be  used 

at  my  own  risk  and  agree  to  hold  harmless  and  indemnity  from  all  claims  for  damages  and  liabilities  resulting  from  its 
improper use. 

 

PLEASE PROVIDE YOUR PURCHASE INFORMATION: 

 

Purchase Date

:

                         Serial No

.

:                                       Model No

.

:                               

 

Name of SALES DISTRIBUTOR this unit was purchased from

 :

 

                                                                           

 

YOUR COMPANY Name

 :

                                                                                                                

Address 

                                                                            Phone

 :

                                          

           

State,City,Zip

 : 

                                                                     

      FAX 

                                       

 

EMAIL

:

                                                                                                                                

Customer Signature

 

:

                                                     

    Print Name 

:

                                                 

 

Please fill-in the lines above, and send a signed copy to 

EMC, 

and keep a copy of this page for your file

.

 

 

Send via 

FAX 

or 

Mail

 to

:

   

E

quipment 

M

anufacturing 

C

orporation 

14930 Marquardt Avenue 
Santa Fe Springs, CA 90670 

FAX:    562 

– 623 – 9342        

Email:    [email protected] 

 

Summary of Contents for POWERJET

Page 1: ...ECTION and USE of the EMC POWERJET PARTS WASHER and SAVE FOR FUTURE REFERENCE Standard Models 2846E 4046E 5846E And Option Models 4046G 5846G 2846E SS 4046E SS 5846E SS 4046G SS 5846G SS OWNER s MANUA...

Page 2: ...m The EMC POWERJET is designed for use with water based Non Flammable fluids only The user is responsible for determining the applicability of their fluid with the materials of construction and functi...

Page 3: ...from the pallet until Ready to Install the unit If there is any damage the following policy and procedures apply D Damaged Merchandise Freight Claims When the product is shipped from EMC it is new un...

Page 4: ...B Basic Frame Height C Floor to Top of TurnTable Shelf Adjustable D Depth Front to Rear E Door Swing Clearance F Foot Pad Width Side to Side G Total Width Side to Side V Vent Stack Inside Diameter 28...

Page 5: ...ssis of the washer IMPORTANT The chassis of this washer MUST be Properly Grounded B THREE PHASE HEATER HOOKUP These Washers have 3 or more Immersion Heaters Each Heater draws approximately 18 amps eac...

Page 6: ...ve Therefore carbon steel Parts Washers are designed for use with water and soap with rust inhibitors The rust inhibitors not only protect the washer cabinet but also the customers steel and iron item...

Page 7: ...ifold To Turn Table Lowest position D Top Rotor Bar To Turn Table Lowest position E Manifolds Side to Side F Rotor Bars Side to Side G Floor to Turn Table top Lowest position 2846 46 44 42 40 28 25 23...

Page 8: ...the proper parts baskets or racks or fixtures as needed to hold or contain loose or small parts 2 Set the Wash Cycle Timer It is the 30 Minute Timer Knob and Indicator Light located at the upper front...

Page 9: ...and volume of activity the Soap Water solution in your washer will need to be changed from time to time In some cases this can be every week or twice a month or once a month or even less often but in...

Page 10: ...le Next you will need to DRAIN some of your wash water solution from the Tank down to a level BELOW the Pump Casing PUMP CASING VOLUTE 3 Remove Drip Cover 2 screws and small plastic end cap 4 Remove I...

Page 11: ...stallation Protect the faces Install both the seat and rotary square to the shaft Check stationary seat installation from behind seat cavity for squareness STATIONARY SEAT Clean seal cavity in pump ad...

Page 12: ...STAT 7 DAY TIMER TO TURNTABLE MOTOR PUMP CONTACTOR HEATER CONTACTOR 30 20 10 Turn Past 0FF MINUTES OFF 2 2 0 1 2 0 1 6 0 200 1 8 0 1 4 0 10 0 AC POWER IN 220V 3 40A Ground to chassis Control Box Front...

Page 13: ...h of a different color connect to the bottom right side main terminal of the Heater Contactor Single Phase Power LINE IN WIRING GROUND connection is to the chassis same as the Three Phase hook up LINE...

Page 14: ...HEATER CONTACTOR Control Box Front View Control Box Rear View Control Box Side View cover removed AC POWER IN 440V 3 20A Ground to chassis Electric models 2846E 4046E 1 5HP 440V 3ph 20A Heater Box Cov...

Page 15: ...Relay HEATER CONTACTOR TO TURNTABLE MOTOR AC POWER IN 220V 3 40A Ground to chassis Control Box Front View Control Box Rear View Control Box Side View cover removed Electric models 2846E 4046E 5HP 220V...

Page 16: ...MOTOR AC POWER IN 440V 3 20A Ground to chassis Control Box Front View Control Box Rear View Control Box Side View cover removed Electric models 2846E 4046E 5HP 440V 3ph 20A Thermostat Probe in sleeve...

Page 17: ...R IN 220V 3 80A Ground to chassis Control Box Front View Control Box Rear View Control Box Side View cover removed Electric models 5846E 5HP 220V 3ph 80A To Pump Contactor Power In Heater Box Cover cu...

Page 18: ...PUMP CONTACTOR Over Load Relay TO TURNTABLE MOTOR AC POWER IN 440V 3 40A Ground to chassis Copper Capillary Tubing Control Box Front View Control Box Rear View Electric models 5846E 5HP 440V 3ph 40A T...

Page 19: ...HEATER CONTACTOR PUMP CONTACTOR Over Load Relay TO TURNTABLE MOTOR AC POWER IN 220V 3 20A Ground to chassis white wire black wire white wire black wire Control Box Front View Control Box Rear View GAS...

Page 20: ...Pulley on model 4046 and larger since March 2015 begin s n9296215 PJ126 SPINDLE NUT taller nut PJ127 ROLLER BEARING CONE CUP ASSEMBLY PJ128 STAND OFF SHIMS under Bearing 2 pieces PJ129 SPINDLE SEAL I...

Page 21: ...hermostat KNOB degrees numbered dial knob 1 STANDARD PUMP MOTOR ITEMS PSK300 PUMP SEAL KIT includes 2 Seals with 2 Lube packs and 1 O Ring PJ301 1ph Std Pump MOTOR 220V 1 phase 1 HP 56J ODP 25 PJ301 3...

Page 22: ...07 001 IGNITION TRANSFORMER 7300V 5 60186 004 24 Volt TRANSFORMER 2 63263 005 Pressure Vacuum SWITCH 2 diam Black White plastic disk 1 Clear Hose for above switch x 9 Length 1 100968 002 Hose Barbed F...

Page 23: ...or and Manifold Drive Belt slipping on Pulley Belt DriveMotor Not functioning Check for Loose Parts sticking out Adjust Drive Belt tension Replace Belt DriveMotor GearMotor Leaking around cabinet or w...

Page 24: ...em The EMC POWERJET is designed for use with water based Non Flammable fluids only The user is responsible for determining the applicability of their fluid with the materials of construction and funct...

Page 25: ...y outlined above are exclusive and total liability of EMC or its Distributor with respect to this sale or the equipment and service furnished hereunder in connection with the performance or breach the...