background image

 

 
 

 
 

 
 

 

 

Operation  

The LEDs

 

display the power levels, intensity level 

and run-on function of the ventilator.

 

 

Display

 

The power levels, intensity level and run-on 
function are shown in the display on the moving 
section. 
 

                                               

 

 

   

Fan ON/OFF 

 

   

Reduced fan level 

  

Increased fan level 

               Run-on,  if  this  button  is  pressed,  the 

ventilator continues to operate at level 

and switches off automatically after 
15 minutes. 

   

Move hood upwards 

 

  

  Move hood downwards 

 
The fan has 3 power levels for normal use and an 
intensity level for occasional use with an 
increased power setting. After 30 minutes, the 
control automatically switches the intensity level 
back to level 3.  
 

It is recommended to allow the fan to continue 
operating for a few minutes after cooking. This 
helps to remove any remaining steam and odours 
from the air. 
The run-on function provides the option of having 
the fan switch off automatically after 15 minutes. 
 
The extractor fan features a filter cleaning display 
which reminds you to clean the filters after 30 
hours of service. 
After this operating time, the power level display 
flashes.  

After cleaning the filters, the 

 button is 

pressed until the power level display flashes.  
The filter cleaning display then starts again from 
zero. 
 

Cleaning and care

 

Visible soiling must be removed from the fat 
filters. 
Excessively greasy filters pose a fire risk. 
To clean the filters remove these from the 
extractor fan using the filter key. The filters are 
attached at the top with a magnetic tape and 
hooked in place on the bottom. 

 

If necessary, the metal filter can be 
removed from the filter housing for 
cleaning. 

 

These parts can be cleaned in a dishwasher or 
with hot water and a cleaning agent. 

Do not use a 

 

high-pressure cleaner

 
 
 
 

Summary of Contents for Downdraft

Page 1: ...for EMB DOWNDRAFT EXTRACTOR HOOD as of 08 2016 Assembly and operating instructions ...

Page 2: ...xtraction mode Page 3 Installation for recirculation mode Page 3 Assembly of foot extensions Page 4 Assembly Page 4 Electrical connection for extraction mode Page 4 Electrical connection for recirculation mode Page 5 Initial operation Page 5 Notes Page 6 Initialisation run Page 6 Maintenance Page 6 No function Page 7 EMB Edelstahl Möbel Beck Brückenstraße 11 74219 Möckmühl Züttlingen Germany Tel 4...

Page 3: ... together with a gas hob a safety switch is required which only allows the air to be extracted in the upper position Warranty claims cannot be asserted for any damage which results from failure to observe these instructions We reserve the right to make technical changes Before using for the first time Before putting the device into use please note the information below Read the assembly and operat...

Page 4: ...emaining steam and odours from the air The run on function provides the option of having the fan switch off automatically after 15 minutes The extractor fan features a filter cleaning display which reminds you to clean the filters after 30 hours of service After this operating time the power level display flashes After cleaning the filters the button is pressed until the power level display flashe...

Page 5: ... authorised specialist Observe the assembly instructions and local installation requirements Before disposing of the packaging material make sure there are no more accessories in the packaging Check the device for transport damage prior to assembly The user must be informed on how to de energise the device if necessary With extraction mode The exhaust air can be guided in all directions the releva...

Page 6: ...aces towards the cooking area Lift the device into the cut out by turning out the adjustable feet To set the final height place the cover on the device Set the height so that the cover is flush with the work surface Align the device vertically Kitchen work surfaces which are thinner than 34 mm can be prevented from sagging by using thread screws M4x25 which are screwed into the upper frame Connect...

Page 7: ...hood several times and observe whether the device runs in parallel After aligning the device and using for the first time secure it in a suitable place using the mounting brackets supplied The brackets can be attached to the screws of the device cladding or the screws in the side parts Attach the brackets as far down as possible The top of the device is fixed in place in the work surface cut out a...

Page 8: ...down the button for a further 10 seconds The system is lowered slightly and lifted up again during initialisation The initialisation run is then complete Please do not let go of the down button during the initialisation run If you let go of this button before the run is complete this process is interrupted and must be started again If the initialisation run is interrupted the system cannot be move...

Reviews: