background image

User Manual 

SHR900X  -  SHR1200X 

Summary of Contents for SHR1200X

Page 1: ...User Manual SHR900X SHR1200X ...

Page 2: ...eight please refer to the paragraphs on working dimensions and installation If the instructions for installation for the gas hob specify a greater distance this must be respected Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules For Class...

Page 3: ...o be adopted for fume discharging it is important to closely follow the regulations pro vided by the local authorities WARNING Before installing the Hood remove the protective films Use only screws and small parts in support of the hood WARNING Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards Do not look directly at the light thr...

Page 4: ...els not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential ne...

Page 5: ...Suction Unit Filters 2 Reinforced ceiling Q ty Documents 1 Instruction and maintenance 1 Installation instructions Warning do not exceed a distance of 1600 mm between the cooker Hob and the Hood in this case the ceiling to guarantee that the cooking fumes will be captured properly Min 600 mm Min 650 mm EN 5 ...

Page 6: ...e paragraph Maintenance being sure that the connector of the feeding cable is correctly inserted in the socket placed on the side of the fan Fixing the Hood In all cases where the ceiling is not strong enough at the suspension point the installer must provide strengthening using suitable plates and backing pieces anchored to the structurally sound parts EN 6 ...

Page 7: ...on of the activated charcoal filters T2 Turn the suction motor on at speed two On Press and hold for approximately 5 seconds with all the loads turned off Motor and Lights to enable disable the Remote control 2 flashes Remote control Enabled 1 flash Remote control Disabled T3 Turn the suction motor on at speed three On Press and hold the button for 2 seconds to activate intensive speed This speed ...

Page 8: ...lighting system on and off Press and hold for approx 2 seconds to turn the lighting system on and off at reduced intensity INTENSIVE It cannot be activated if the Delay function is in use Activates Deactivates Intensive speed Intensive speed is timed to run for 6 minutes At the end of the 6 minutes the system will automatically return to the speed that was set before DELAY FUNCTION Activates Deact...

Page 9: ... This cannot be washed or regenerated and must be changed when all the command LEDs start to flash or at least once every 4 months Activating the alarm signal In Recirculation Version Hoods the Filter Saturation Alarm must be activated on installation or at a later date Press and hold the Delay button T4 on the keypad for 5 seconds and the following will be displayed Leds L1 L2 L3 flash twice Acti...

Page 10: ...0 10 16 G13 95 720 x 26 FD 16 40 1B E G13 26 720 18 G13 57 589 8 x 26 FD 18 40 1B E G13 26 600 9 G23 60 lamp 220 240 starter 167 x 28 FSD 9 27 1B I G23 11 G23 91 lamp 220 240 starter 235 8 x 28 FSD 11 40 1B I G23 EN 10 Lighting LIGHT REPLACEMENT Halogen lamps Open the spotlight cover Remove the halogen lamp from the lamp holder Replace it with another lamp that has the same characteristics making ...

Page 11: ......

Page 12: ...991 0562 331_01 180910 D0005186_00 ...