Clean the housing at regular intervals using
warm soapy water.
To prevent stripes from forming, treat the
stainless steel surfaces with a care product,
e.g., EMB Etolit stainless steel finish. Always
work in the surface’s grinding direction and do
not use abrasive sponges or strong or corrosive
cleaning products.
No items must fall between the plastic guide
and the stainless steel housing.
Installation
Safety instructions.
Caution, risk of injury!
Sharp edges.
Caution, risk of tilting!
Only place the device upright on the floor if
secure.
Caution! Do not squash the connecting cables
during assembly.
Downdraft ventilation is intended for
combination with electrical devices.
If extraction is used behind a gas hob, a safety
switch is installed which only allows the exhaust
function to be switched on in the top most
position.
This must be stated on ordering the device.
To achieve optimal extraction, the downdraft
ventilation system must be installed as close as
possible to the cooking area.
The cut-outs must be made in accordance with
our installation drawings.
The device may only be connected up and put
into operation by an authorised specialist.
Observe the assembly instructions and local
installation requirements.
Before disposing of the packaging material, make
sure there are no more accessories in the
packaging.
Check the device for transport damage prior to
assembly.
The user must be informed on how to de-
energise the device if necessary.
With extraction mode
The exhaust air can be guided in all directions,
the relevant connection parts must be stated
when placing the order (in part special
accessories).
Note: The exhaust air must not be emitted into
an operational smoke or exhaust gas flue.
If the exhaust air is to be guided into a non-
operational smoke or exhaust gas flue,
approval must be obtained from the
competent master chimney sweep.
The official and legal regulations (e.g., state
building codes) must be observed when
expelling exhaust air.
If the exhaust air is expelled via the outer wall,
a telescopic wall sleeve must be used.
Accessories for extraction mode
Round tube system for extraction mode
Flat channel system for extraction mode
With recirculation mode
Access to the controls and for changing the
activated carbon filters must be provided from
behind or front.
The recirculated air is returned via the base of
the furniture. Please refer to the technical data
for details on the cross-section required for the
air return.