background image

 

Clean the housing at regular intervals using 
warm soapy water. 
To prevent stripes from forming, treat the 
stainless steel surfaces with a care product, 
e.g., EMB Etolit stainless steel finish. Always 
work in the surface’s grinding direction and do 
not use abrasive sponges or strong or corrosive 
cleaning products. 
No items must fall between the plastic guide 
and the stainless steel housing. 

 

Installation

 

 

Safety instructions.

 

Caution, risk of injury! 
Sharp edges. 

 

Caution, risk of tilting!  
Only place the device upright on the floor if 
secure. 

 

Caution! Do not squash the connecting cables

 

during assembly.

 

 

Downdraft ventilation is intended for 
combination with electrical devices. 
If extraction is used behind a gas hob, a safety 
switch is installed which only allows the exhaust 
function to be switched on in the top most 
position. 
This must be stated on ordering the device. 
 
To achieve optimal extraction, the downdraft 
ventilation system must be installed as close as 
possible to the cooking area. 
The cut-outs must be made in accordance with 
our installation drawings. 

The device may only be connected up and put 
into operation by an authorised specialist. 
Observe the assembly instructions and local 
installation requirements.  

 

Before disposing of the packaging material, make 
sure there are no more accessories in the 
packaging. 
Check the device for transport damage prior to 
assembly. 
 
 
 

The  user  must  be  informed  on  how  to  de-
energise the device if necessary. 

With extraction mode

 

The exhaust air can be guided in all directions, 
the relevant connection parts must be stated 
when placing the order (in part special 
accessories). 

 

 

Note: The exhaust air must not be emitted into 
an operational smoke or exhaust gas flue. 
If the exhaust air is to be guided into a non-
operational smoke or exhaust gas flue, 
approval must be obtained from the 
competent master chimney sweep. 
The official and legal regulations (e.g., state 
building codes) must be observed when 
expelling exhaust air. 
If the exhaust air is expelled via the outer wall, 
a telescopic wall sleeve must be used. 

Accessories for extraction mode 

Round tube system for extraction mode 
Flat channel system for extraction mode 
 

With recirculation mode

 

Access to the controls and for changing the 
activated carbon filters must be provided from 
behind or front. 
The recirculated air is returned via the base of 
the furniture. Please refer to the technical data 
for details on the cross-section required for the 
air return. 

            

 

    

 
 
 
3         

Summary of Contents for Downdraft

Page 1: ...for EMB DOWNDRAFT EXTRACTOR HOOD as of 08 2016 Assembly and operating instructions ...

Page 2: ...xtraction mode Page 3 Installation for recirculation mode Page 3 Assembly of foot extensions Page 4 Assembly Page 4 Electrical connection for extraction mode Page 4 Electrical connection for recirculation mode Page 5 Initial operation Page 5 Notes Page 6 Initialisation run Page 6 Maintenance Page 6 No function Page 7 EMB Edelstahl Möbel Beck Brückenstraße 11 74219 Möckmühl Züttlingen Germany Tel 4...

Page 3: ... together with a gas hob a safety switch is required which only allows the air to be extracted in the upper position Warranty claims cannot be asserted for any damage which results from failure to observe these instructions We reserve the right to make technical changes Before using for the first time Before putting the device into use please note the information below Read the assembly and operat...

Page 4: ...emaining steam and odours from the air The run on function provides the option of having the fan switch off automatically after 15 minutes The extractor fan features a filter cleaning display which reminds you to clean the filters after 30 hours of service After this operating time the power level display flashes After cleaning the filters the button is pressed until the power level display flashe...

Page 5: ... authorised specialist Observe the assembly instructions and local installation requirements Before disposing of the packaging material make sure there are no more accessories in the packaging Check the device for transport damage prior to assembly The user must be informed on how to de energise the device if necessary With extraction mode The exhaust air can be guided in all directions the releva...

Page 6: ...aces towards the cooking area Lift the device into the cut out by turning out the adjustable feet To set the final height place the cover on the device Set the height so that the cover is flush with the work surface Align the device vertically Kitchen work surfaces which are thinner than 34 mm can be prevented from sagging by using thread screws M4x25 which are screwed into the upper frame Connect...

Page 7: ...hood several times and observe whether the device runs in parallel After aligning the device and using for the first time secure it in a suitable place using the mounting brackets supplied The brackets can be attached to the screws of the device cladding or the screws in the side parts Attach the brackets as far down as possible The top of the device is fixed in place in the work surface cut out a...

Page 8: ...down the button for a further 10 seconds The system is lowered slightly and lifted up again during initialisation The initialisation run is then complete Please do not let go of the down button during the initialisation run If you let go of this button before the run is complete this process is interrupted and must be started again If the initialisation run is interrupted the system cannot be move...