WATER COMFORT SYSTEM

 

 

Operating manual

 

electronic temperature control unit for ELSR-W

 

 

 

Art.: 0630000

 

 

Type:  ELTC-W

 

 

eltherm Water Comfort System

 

– simply energy-saving

 

 

In modern society the supply of pure potable and non po-

 

table water, both hot and cold, is an important contribution

 

to comfort and well-being which should be readily available. 
We assume that the water supply is clean and sterile, but 
unfortunately this is not always true. An invisible threat to 
health is legionella bacteria. These bacteria cause two kinds 
of clinical problems, which behave differently in the course

 

of disease. One known as Legionnaires Disease normally 
causes symptoms similar to pneumonia and can result in 
death. The second one so called Pontiac Fever has symp- 
toms like influenza but with quite rapid healing.

 

 

Legionella, especially in heated water between 30° and

 

45°C, can cause a threat to health, if small drops of water, 
e.g. when taking a shower, are inhaled. Legionella formation 
can be prevented by merely changing the water tempera- 
ture. Cold water under 20°C and warm water over 55°C 
constitute poor growth conditions for legionella bacteria, 
therefore the water should be heated up to 60°C once a

 

day to purge the system. This procedure is called thermal 
disinfection.

 

 

If the disinfection measures are incorporated in the planning 
phase of a water line system, remarkable cost savings can 
be achieved. However, retrofitting of a thermal disinfection 
system is normally possible without any problems. It is 
especially important to install the system in buildings which 
present high risk of infection to the occupants, such as hos- 
pitals, nursing homes and schools, but it also makes sense 
to install the system in private housing.

 

 

The eltherm Water Comfort System provides the energy- 
saving solution to keep warm water steadily available and to 
fight legionella bacteria effectively.

 

Advantages of the eltherm Water Comfort System for you:

 

 

High user friendliness by intuitive adjustment

 

Simplified entry. A lot of details are already 
preset for choice

 

Logical and clear composed menu 

– no 

confusing icons

 

Complicated calculations to adjust the system

 

are not necessary

 

An automatic operating mode ensures 
legionella bacteria prevention even if the 
system is not adjusted individually already.

 

No overheating of the system because of 
heating and heat maintenance with self- 
regulating heating tapes.

 

The moisture proof heating tape ensures 
longer durability.

 

The heating tape is available in three nominal 
outputs.

 

The length of the heating tape can be varied 
freely as you can cut it to length from roll.

 

An additional heating circuit for frost protection 
in combination with a self-regulating

 

heating tape prevents freezing of an 
additional cold water pipe.

 

Cost saving up to 65%, because a circulation 
system and a circulation pump is no longer needed.

 

Considerable energy saving because of optimized 
temperature gradation and abolition of the 
circulation pump.

 

An additional temperature sensor on the boiler 
enables in ideal temperature maintenance balanced 
between boiler and water pipes

 

Ideally matching accessories enable an 
individual design according to your require- 
ments => a plug-and-play version is possible 
if wished

 

The system fulfills accepted international 
standards for legionella avoidance (e.g. 
Arbeitsblatt W 551 of DVGW in Germany)

 

The system is approved by VDE and fulfills

 

the EN 61000-3-3/11.* That means, because of 
the soft start function there is no flickering light 
when energizing the heating tape.

 

 

The considerable simplification of installation makes the 
eltherm Water Comfort Systems to the optimal solution for 
drinking water heating and drinking water conduit facilities.

 

 

 

* "Flicker" Standard. Please contact us for details.

 

 

BU-091 - 008TCWE                                                              Firmware V0.5.0 

Revision 3

 

Summary of Contents for 0630000

Page 1: ...using The eltherm Water Comfort System provides the energy saving solution to keep warm water steadily available and to fight legionella bacteria effectively Advantages of the eltherm Water Comfort System for you High user friendliness by intuitive adjustment Simplified entry A lot of details are already preset for choice Logical and clear composed menu no confusing icons Complicated calculations ...

Page 2: ...ss due to double piping power for pump Warm water electrical heat tracing system This system uses the same principle as the warm water cir culation system but does not require a circulation pipe pump valves and fittings associated with the circulation pipe Instead a self regulating heating cable is used for temperature mainte nance With electrical heat tracing warm water is provided all the way to...

Page 3: ...undeinstellungen Base Settings RET select a parameter list select parameter to be programmed RET start programming parameter name blinks ESC Optionally an identification is required choose settings keeping cursor button pushed accelerates the display of data ELTC W 10 49 WE 2 Setup RET Sollwerte Einstellung Settings RET end programming ESC brings you back to list overview ESC ELTC W 10 50 WE 3 Tim...

Page 4: ...andard busbar 35mm IP 20 Danger It presents a danger to life A safe operation might not be possible if the device has visible damage the device does not work after longer storage in inappropriate conditions contamination or humidity after hard transport stress Installation and operation of the device must be carried out by a certified electrician or under observation by a certified electrician Kee...

Page 5: ...e time On the daily date switch 23 59 0 00 the output is operated for a deter mined time of 2 hours for legionella bacteria reduction with 100 power On the display the remaining time round up number of days with a maximum of 99 days is shown which means if the remaining time is under 24 hours the display shows 1 day Frost Protection By setting the parameter ActivateA F the frost protection functio...

Page 6: ...mum expected temperature at pipe location The diameter of water pipe The thickness of insulation Can be used to adjust the internally calculated power output to local conditions If the Trace Boiler function is activated the ELTC W will follow the temperature of the boiler Therefore a temperature sensor is needed at boiler surface If boiler probe detects this temperature or above legionella protect...

Page 7: ...1 08 00 Uhr Maint temp 2 08 01 11 00 Uhr Economy Mode 1 11 01 13 00 Uhr Maint temp 2 13 01 16 00 Uhr Economy Mode 1 16 01 22 00 Uhr Maint temp 2 22 01 23 59 Uhr No heating 0 enter menu ELTC W 10 49 WE Standard mode Standard Display Restaurant 00 00 02 00 Uhr Economy Mode 1 02 01 03 00 Uhr Legionella protection 3 03 01 06 30 Uhr No heating 0 06 31 08 00 Uhr Economy Mode 1 select function Timer pres...

Page 8: ...ere are three wiring schemes for the temperature controller LED Operation 230V supply input B 24VDC Interface Service Port sensor inputs Frost Protection Boiler DO NDO Gnd Gnd F1 Gnd F2 2 A N Block PE Block N N N PE PE PE L A L1 L1 L heating tape Com NO Com NO NC frost protection output max 16 A alarm output max 2 A L A supply voltage controller ELTC W L1 supply voltage heating tape L heating tape...

Page 9: ...Gnd Gnd F1 Gnd F2 2 A N Block PE Block N N N PE PE PE L A L1 L1 L heating tape Com NO Com NO NC Advice frost protection output max 16 A alarm output max 2 A L A supply voltage controller ELTC W L1 supply voltage heating tape L heating tape output Wiring Scheme 2 If the heater and the temperature controller are connected on same feeding circuit the system has to be protected with C 20A max Advice A...

Page 10: ...terface Service Port sensor inputs Frost Protection Boiler supply input B 24VDC DO NDO Gnd Gnd F1 Gnd F2 2 A N Block PE Block N N N PE PE PE L A L1 L1 L heating tape Com NO Com NO NC frost protection output max 16 A alarm output max 2 A L A supply voltage controller ELTC W L1 supply voltage heating tape L heating tape output Wiring Scheme 3 Connect separate 24 VDC supply for controller as shown ab...

Reviews: