Checking the usage

Diaphragm gas meters BK-G.6 to G5

Residential or commercial diaphragm gas meters 
BK for recording gas consumption values for natural 
gas, town gas, propane and butane, as gases of the 
first to third families pursuant to DIN EN 437:2003 
(DVGW Code of Practice G260). If used for internal 
measurements which are not subject to statutory 
testing, the gas meter is also suitable for hydrogen, 
nitrogen, air and inert gases.

BK with integrated “Smart Valve”

Not suitable for highly contaminated gases, e.g. 
town gas.

Potentially explosive atmosphere

Diaphragm gas meters that are labelled with 

 

and 

 (see sticker near the index) are suitable for 

operation in potentially explosive atmospheres, see 
page 7 (Declaration of conformity).

The meter function is only guaranteed when used 

under the specified operating conditions  – see 
page  7 (Technical data). Any other use is con-
sidered as non-compliant.

Type code

Code

Description

BK-G

Diaphragm gas meter

 

.6 

.5 

0 
6 

5

Flow rate 

0.016 – 2.5  m

3

/h 

0.025 – 4  m

3

/h 

0.04 – 6  m

3

/h 

0.06 – 10  m

3

/h 

0.1 – 16  m

3

/h 

0.16 – 25  m

3

/h 

0.25 – 40  m

3

/h



B

Mechanical index 

Chekker mechanical index 
Absolute ENCODER index 

Electronic index 

Indication of volume at base conditions

 


Te
TB 

Temperature conversion: 

mechanical 

electronic

mechanical-electronic temperature 

 conversion and pressure correction

Part designations

2

1

3

4

6

5

  Diaphragm gas meter BK

  Index with index plate

 Connectors

4

  Protective caps

5

  2 x thermowells (optional)

6

  Pressure test point with sealing sleeve (optional)

Type label/Index plate

Diaphragm gas meters BK-G..M..

m

3

,

-

BK-G..M..

12345678

DE-07-MI002-PTB001

class 1,5

NG-47001BM0443 DIN EN 1359:2007

Q

 

max

 

Q

 

min

 

002545632734 

1 imp =^  

        0,01 m

3

DE-07-MI002-PTB001
002545632734

class 1,5

NG-47001BM0443 DIN EN 1359:2007

BK-G..A..

ENCODER 

VALVE Vs

M12  0102

M12  0102

m

3

,

-

Diaphragm gas meters BK-G..A.. with 

Absolute ENCODER index

m

3

,

-

BK-G..M..

12345678

DE-07-MI002-PTB001

class 1,5

NG-47001BM0443 DIN EN 1359:2007

Q

 

max

 

Q

 

min

 

002545632734 

1 imp =^  

        0,01 m

3

DE-07-MI002-PTB001
002545632734

class 1,5

NG-47001BM0443 DIN EN 1359:2007

BK-G..A..

ENCODER 

VALVE Vs

M12  0102

M12  0102

m

3

,

-

Diaphragm gas meters BK-G..E

BK-G..E..

DE-07-MI002-PTB001

002545632734 

class 1,5

Q

 

max 

Q

 

min 

M12  0102

12345678

Diaphragm gas meters BK-G..E themis

log

BK-..E

002519280846 

2013

class 1,5

Q

 

max

 

Q

 

min

 

V

p

 

max

 

t

 

m

 t

 

g

 

M13 0102

12345678

Diaphragm gas meters BK-G..B

BK-..B

002545632734 

class 1,5

Q

 

max

 

Q

 

min

 

M12  0102

Vb

12345678

Summary of Contents for BK-G Series

Page 1: ...transported in the upright position On receipt of the product check that the delivery is complete see Part desig nations Report any transport damage immediately Storage Diaphragm gas meters are always to be stored in the upright position and in a dry place Ambient tempera ture see Technical data Changes to edition 05 13 The following chapters have been changed Checking the usage Commissioning Main...

Page 2: ...hekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te TB Temperature conversion mechanical electronic mechanical electronic temperature conversion and pressure correction Part designations 2 1 3 4 6 5 1 Diaphragm gas meter BK 2 Index with index plate 3 Connectors 4 Protective caps 5 2 x thermowells optional 6 Pressure test point with sealing s...

Page 3: ...ermany TÜV 12 ATEX 098560 X II 2 G IIA T4 Use as follows Category internal none external Category 2 Zone 1 Type of atmosphere gases hazes and vapours Installation WARNING Please observe the following to ensure that neither persons nor the gas meter are damaged during installation and operation Note the max allowable operating pres sure pmax and measuring range Qmax see page 2 Type label Index plat...

Page 4: ...Anzugsmomente für BK G1 6 bis BK G25 Supplement to BK operating instructions Screw unions and tightening tor ques for BK G1 6 to BK G25 D 2 Install the gas meter free of mechanical stress If a pulse transmitter IN Z6x is used for pulse tapping on the gas meter marked with see Data sheet for pulse transmitter IN Z6x D GB www docuthek com Elster Instromet Prod ucts Gas measuring devices Diaphragm me...

Page 5: ...g the pulse transmitter IN Z6x can be connected see Data sheet for pulse transmitter IN Z6x D GB www docuthek com Elster Instromet Products Gas measuring devices Diaphragm meters Pulse transmitter IN Z61 BK G A with Absolute ENCODER index AE1 Z6 Interface description for gas meters with ENCODER index see Specification GB www docuthek com Elster Instromet Products Archive Gas measuring devices BK G...

Page 6: ...eleases the gas supply If consumers of the customer are open pressure equalization cannot occur and the valve remains in the Released position and continues to release only the minimum gas flow rate of the bypass Closed The valve and the bypass are closed in the event of remote shut down All valve positions are kept de energized Maintenance Removal Gas meters BK G1 6 to 25 from Elster are mainte n...

Page 7: ...i 30 mA Pi 33 mW Ci 140 µF Li 0 µH Diaphragm gas meters BK with integrated valve Vp Opening time 4 s Closing time 0 5 s Max operating pressure 100 mbar Leakage flow closed max 5 l h The specified leakage flow rate is also complied with at pressures 100 mbar e g in the event of a fault Diaphragm gas meters BK with integrated Smart Valve Vs Not suitable for highly contaminated gases e g town gas Ope...

Page 8: ...ische Bundesan stalt German National Metrological Institute Notified Body 0102 Markings M 0102 DE 11 MI002 PTB001 After the M the year of construction is given EMC EC Directive 2004 108 EC EMC Standards OIML D11 2004 Sec 12 EN 55022 2006 A1 2007 ETSI EN 301 489 17 V2 1 1 ETSI EN 301 489 1 V1 8 1 Tests and inspections EMC Test NRW GmbH Test Report No P10 Z 00086 002 P13 Z 00096 001 TRaC Global Ltd ...

Page 9: ...en EMC EC Directive 2004 108 EC EMC Standards EN 55022 2006 A1 2007 Class B EN 61000 4 2 2009 EN 61000 4 3 2006 A1 2008 A2 2010 EN 61000 4 4 2004 A1 2010 EN 61000 4 5 2006 EN 61000 4 6 2009 EN 61000 4 12 2006 EN 61000 4 8 2010 IEC 61000 6 3 2006 Class B Tests EMV Testhaus GmbH Test Report No 120393 AU01 E01 NMi Certin B V Test Report NMi 12200781 03 R TTE EC Directive 1999 5 EC R TTE Standards EN ...

Page 10: ...eaconside Stafford ST16 3EF T 44 1785 275200 F 44 1785 275305 jeavons info gb elster com www elstermetering co uk Ireland Active Energy Control Ltd Unit 4 Clare Marts Quin Road Ennis Co Clare T 353 65 6840600 F 353 65 6840610 info aec ie www aec ie Germany Elster GmbH Strotheweg 1 49504 Lotte T 49 541 1214 0 F 49 541 1214 370 info elster instromet com www elster instromet com Contact ...

Reviews: