Technical data

Diaphragm gas meter BK

Gas type: natural gas, town gas, propane and butane, 
as gases of the first to third families pursuant to 
DIN EN 437:2003 (DVGW Code of Practice G260).

The following technical data can be found on the 

type label/index plate:

– 

max. allowable operating pressure p

max

– 

measuring range: Q

min

/Q

max

– 

 max. allowable ambient temperature range t

m

– 

max. allowable gas temperature range t

g

*

– 

cyclic volume V

For meters with temperature conversion only:

– 

base gas temperature t

b

– 

specified centre temperature t

sp

**

Other technical data:

– 

transitional flow rate Q

t

 = 0.1 x Q

max

– 

 max. allowable storage temperature range: 

 

-25 to +60°C

– 

mechanical environment class: M1

– 

electromagnetic environment class: E2

Supplementary notes:

 If operated within the gas temperature range, 
the measuring error still lies within the required 

error limits. If no gas temperature t

g

 is specified 

on the index plate, the following applies: t

g

 = t

m

.

**   The specified centre temperature t

sp

 of the BK-

G...E... series and BK-G...B meters is not stated 
on the index plate, but can be called up in the 
display using the menu.

Diaphragm gas meters BK with pressure test 

point

Pressure test point: 24° olive fitting to EN ISO 8434-1, 
L6 x M12 x 1.5-St.

Diaphragm gas meters BK with explosion 

protection

Max. allowable ambient temperature range t

m

 /gas 

temperature range t

g

: -25 to +55°C; for constraints, 

see type label/index plate.
In addition, the following interface parameters apply 
for BK-G...A/AT:
U

i

 = 5.5 V

I

i

 = 30 mA

P

i

 = 33 mW

C

i

 = 140 µF

L

i

 = 0 µH

Diaphragm gas meters BK with integrated 

valve Vp

Opening time: ≤ 4 s.
Closing time: ≤ 0.5 s.
Max. operating pressure: 100 mbar.
Leakage flow (closed): max. 5 l/h.

 

The specified leakage flow rate is also complied 

with at pressures > 100 mbar (e.g. in the event 
of a fault).

Diaphragm gas meters BK with integrated 

“Smart Valve” Vs

Not suitable for highly contaminated gases, e.g. 
town gas.
Opening time (from closed to open/released state): 

≤ 4 s.

Closing time: ≤ 0.5 s.
Min. operating pressure: 17.5 mbar.

Allowed leakage flow in the customer’s piping:
valve released: max. 13 l/h at 35 mbar, 
valve closed: max. 5 l/h.

Declaration of conformity

Scan of the following Declarations of conformity – see 
www.docuthek.com

Diaphragm gas meters BK-G..M, BK-G..C, 

BK-G..MT, BK-G..CT

We, the manufacturer, hereby declare that the prod-

ucts labelled accordingly comply with the require-
ments of the listed Directives and Standards:

– 

 MID 
EC Directive: 2004/22/EC – MID

 Standard: 
 

DIN EN 1359:2007 (EN 1359:1998+A1:2006)

 

 EC  type-examinations:

 

DE-07-MI002-PTB001, DE-07-MI002-PTB002.

 

 The production is subject to the surveillance 

procedure pursuant to 2004/22/EC, Annex D, 
Physikalisch-Technische Bundesanstalt  (German 
National Metrological Institute), 

 

Notified Body 0102.

 

 Markings:

  

M...

 0102, DE-07-MI002-PTB001 or 

DE-07-MI002-PTB002 

 

 After the “M”, the year of construction is given.

–  

ATEX (only valid if marked on the meter)

 

 EC Directive: 94/9/EC – ATEX

 

 Standards: 
EN 13463-1:2009

 

EN 13463-5:2011

 

 Tests and inspections:

 

 TÜV NORD CERT GmbH, Statement of conform-

ity – No. TÜV 11 ATEX 090370 X.

 

 The production is subject to the conformity 

assessment procedure pursuant to 94/9/EC, 

 Annex VIII.

 

 Markings:

   II -/2 G c IIB TX.
Elster GmbH

Summary of Contents for BK-G Series

Page 1: ...transported in the upright position On receipt of the product check that the delivery is complete see Part desig nations Report any transport damage immediately Storage Diaphragm gas meters are always to be stored in the upright position and in a dry place Ambient tempera ture see Technical data Changes to edition 05 13 The following chapters have been changed Checking the usage Commissioning Main...

Page 2: ...hekker mechanical index Absolute ENCODER index Electronic index Indication of volume at base conditions T Te TB Temperature conversion mechanical electronic mechanical electronic temperature conversion and pressure correction Part designations 2 1 3 4 6 5 1 Diaphragm gas meter BK 2 Index with index plate 3 Connectors 4 Protective caps 5 2 x thermowells optional 6 Pressure test point with sealing s...

Page 3: ...ermany TÜV 12 ATEX 098560 X II 2 G IIA T4 Use as follows Category internal none external Category 2 Zone 1 Type of atmosphere gases hazes and vapours Installation WARNING Please observe the following to ensure that neither persons nor the gas meter are damaged during installation and operation Note the max allowable operating pres sure pmax and measuring range Qmax see page 2 Type label Index plat...

Page 4: ...Anzugsmomente für BK G1 6 bis BK G25 Supplement to BK operating instructions Screw unions and tightening tor ques for BK G1 6 to BK G25 D 2 Install the gas meter free of mechanical stress If a pulse transmitter IN Z6x is used for pulse tapping on the gas meter marked with see Data sheet for pulse transmitter IN Z6x D GB www docuthek com Elster Instromet Prod ucts Gas measuring devices Diaphragm me...

Page 5: ...g the pulse transmitter IN Z6x can be connected see Data sheet for pulse transmitter IN Z6x D GB www docuthek com Elster Instromet Products Gas measuring devices Diaphragm meters Pulse transmitter IN Z61 BK G A with Absolute ENCODER index AE1 Z6 Interface description for gas meters with ENCODER index see Specification GB www docuthek com Elster Instromet Products Archive Gas measuring devices BK G...

Page 6: ...eleases the gas supply If consumers of the customer are open pressure equalization cannot occur and the valve remains in the Released position and continues to release only the minimum gas flow rate of the bypass Closed The valve and the bypass are closed in the event of remote shut down All valve positions are kept de energized Maintenance Removal Gas meters BK G1 6 to 25 from Elster are mainte n...

Page 7: ...i 30 mA Pi 33 mW Ci 140 µF Li 0 µH Diaphragm gas meters BK with integrated valve Vp Opening time 4 s Closing time 0 5 s Max operating pressure 100 mbar Leakage flow closed max 5 l h The specified leakage flow rate is also complied with at pressures 100 mbar e g in the event of a fault Diaphragm gas meters BK with integrated Smart Valve Vs Not suitable for highly contaminated gases e g town gas Ope...

Page 8: ...ische Bundesan stalt German National Metrological Institute Notified Body 0102 Markings M 0102 DE 11 MI002 PTB001 After the M the year of construction is given EMC EC Directive 2004 108 EC EMC Standards OIML D11 2004 Sec 12 EN 55022 2006 A1 2007 ETSI EN 301 489 17 V2 1 1 ETSI EN 301 489 1 V1 8 1 Tests and inspections EMC Test NRW GmbH Test Report No P10 Z 00086 002 P13 Z 00096 001 TRaC Global Ltd ...

Page 9: ...en EMC EC Directive 2004 108 EC EMC Standards EN 55022 2006 A1 2007 Class B EN 61000 4 2 2009 EN 61000 4 3 2006 A1 2008 A2 2010 EN 61000 4 4 2004 A1 2010 EN 61000 4 5 2006 EN 61000 4 6 2009 EN 61000 4 12 2006 EN 61000 4 8 2010 IEC 61000 6 3 2006 Class B Tests EMV Testhaus GmbH Test Report No 120393 AU01 E01 NMi Certin B V Test Report NMi 12200781 03 R TTE EC Directive 1999 5 EC R TTE Standards EN ...

Page 10: ...eaconside Stafford ST16 3EF T 44 1785 275200 F 44 1785 275305 jeavons info gb elster com www elstermetering co uk Ireland Active Energy Control Ltd Unit 4 Clare Marts Quin Road Ennis Co Clare T 353 65 6840600 F 353 65 6840610 info aec ie www aec ie Germany Elster GmbH Strotheweg 1 49504 Lotte T 49 541 1214 0 F 49 541 1214 370 info elster instromet com www elster instromet com Contact ...

Reviews: