GB-9
D
GB
F
NL
I
SK
stalt (German National Metrological Institute),
Notified Body 0102.
Markings:
M...
0102, DE-12-MI002-PTB002
After the “M”, the year of construction is given.
–
EMC
EC Directive: 2004/108/EC – EMC
Standards:
OIML D11:2004, Sec. 12
EN 55022:2006+A1:2007
Tests and inspections:
EMC Test NRW GmbH:
Test Report No. P10-Z-00086-002
P13-Z-00096-001
– ATEX (only valid if marked on the meter)
EC Directive: 94/9/EC – ATEX
Standard: EN 1127-1:2007
Tests and inspections:
TÜV NORD CERT GmbH, Statement of conform-
ity – No. TÜV 11 ATEX 093627 X.
The production is subject to the conformity as-
sessment procedure pursuant to 94/9/EC, An-
nex VIII.
Markings:
II -/3 G IIA T1.
Elster GmbH
Diaphragm gas meters BK-G..B
We, the manufacturer, hereby declare that the prod-
ucts labelled accordingly comply with the require-
ments of the listed Directives and Standards:
– MID
EC Directive: 2004/22/EC – MID
Standards:
DIN EN 1359:2007 (EN 1359:1998+A1:2006)
OIML R137-1 & 2 Edition 2012
EC type-examination: T10489 (NMi)
The production is subject to the surveillance pro-
cedure pursuant to 2004/22/EC, Annex D, Physi-
kalisch-Technische Bundesanstalt (German Na-
tional Metrological Institute), Notified Body 0102.
Markings:
M...
0102, T10489
After the “M”, the year of construction is given.
– EMC
EC Directive: 2004/108/EC – EMC
Standards:
EN 55022:2006+A1:2007, Class B
EN 61000-4-2:2009
EN 61000-4-3:2006+A1:2008+A2:2010
EN 61000-4-4:2004+A1:2010
EN 61000-4-5:2006
EN 61000-4-6:2009
EN 61000-4-12:2006
EN 61000-4-8:2010
IEC 61000-6-3:2006, Class B
Tests:
EMV Testhaus GmbH, Test Report
No. 120393-AU01+E01
NMi Certin B.V., Test Report NMi-12200781-03
– R&TTE
EC Directive: 1999/5/EC – R&TTE
Standards:
EN 60950-1:2006+A11:2009+A1:2010
+A12:2001
EN 301 511 V9.0.2
EN 301 489-1 v1.8.1
EN 301 489-7 v1.3.1
Tests:
Phoenix TESTLAB, Test Report No. S130776E1
CETECOM ICT Services GmbH, Test Report No.
M528971Y-01-EO/-CC
–
ATEX (only valid if marked on the meter)
EC Directive: 94/9/EC – ATEX
Standard: EN 1127-1:2007
Tests:
TÜV NORD CERT GmbH, Statement of conform-
ity – No. TÜV 12 ATEX 098560 X.
The production is subject to the conformity as-
sessment procedure pursuant to 94/9/EC, An-
nex VIII.
Markings:
II -/2 G IIA T4.
Elster GmbH
ATEX legend
= Marking of explosion protection
II
= Equipment group ll for general industries
(with the exception of mines)
-/2
= Category:
internal: none
external: Category 2 (Zone 1)
-/3
= Category:
internal: none
external: Category 3 (Zone 2)
G
= Type of atmosphere: gases, hazes and
vapours
c
= “Constructional safety” explosion protec-
tion type
IIB, IIA = Explosion group for gases
TX
= No intrinsic heating
T1
= Temperature class: maximum allowable
surface temperature 450°C
T4
= Temperature class: maximum allowable
surface temperature 135°C