Volume Conversion Device EK260
76
Elster GmbH
PrLog Printer log
Entry point into the submenu "Printer log".
The printer log is used for the cyclical output of formatted data to a printer with a
serial interface conforming to RS-232 and which is connected to the internal
interface (Interface 2).
After entry into the submenu with <ENTER>, settings of the printer log can be
made, such as for example, when a data row is output.
CSync Automatic setting of the clock by rem. data transmission
Entry point into the submenu for setting the function "Automatic setting of the clock
by remote data transmission"
à
3.12.2
GSM.N GSM network
GSM.L Reception level
When using a mobile radio modem and with a suitable setting of
Md.S2
(see
above), information regarding the mobile radio network can be recalled here onc e
the EK260 has logged in.
The information is automatically updated each night at 0:00 and after a failure of
the external power supply. If required, an update can be carried out by pressing
the key combination <ENTER> during the display of
GSM.L
.
Bd.S1 Baud rate, Interface 1
Here, the baud rate (speed) for the data transmission b etween the EK260 and a
device connected to the optical interface can be set.
The standard setting is 9600 Bd. If problems occur with the data transmi ssion,
then this is probably due to the readout lead. Then set Bd.S1 to 4800 Bd (to give a
slower data transmission).
Depending on the system, Bd.S1 can also be set to 19200 Bd. With this setting,
the data transmission does not function correctly. Therefore, avoid using this
setting.
StM
GSM modem log-in status
F
This value is only valid when using a GSM modem.
This value shows in which network the GSM modem is logged in:
Logged out
The GSM modem is currently not logged in.
Possible causes: Call window off, no SIM card inserted, SIM
PIN not entered.
Own network
The GSM modem is logged into its own network.
Searching...
The GSM modem is currently logging into a network.
Denied
The GSM modem log-in has been denied.
Third party
The modem is logged into a third party network ("roaming").
no command
The modem command for reading out the modem status has
not been parameterised. If this text is displayed with a
connected GSM modem, the EK260 has not been correctly
parameterised.
Summary of Contents for 83 462 140
Page 117: ...Volume Conversion Device EK260 Elster GmbH 117 A 2 Approval for Ex Zone 1 ...
Page 118: ...Volume Conversion Device EK260 118 Elster GmbH ...
Page 119: ...Volume Conversion Device EK260 Elster GmbH 119 ...
Page 120: ...Volume Conversion Device EK260 120 Elster GmbH ...
Page 121: ...Volume Conversion Device EK260 Elster GmbH 121 ...