Volume Conversion Device EK260
Elster GmbH
31
3.4 Temperature list
AD
Designation / value
Unit
Access Address DC
T
Temperature
°C
-
6:310_1 4
T.LW
Lower warning limit temperature
°C
S
9:150
8
T.UW
Upper warning limit temperature
°C
S
9:158
8
TMin
Lower alarm limit temperature
°C
C
6:3A8_1 8
TMax
Upper alarm limit temperature
°C
C
6:3A0_1 8
MRL.T
Temperature meas. range lower limit
°C
C
5:224_1 8
MRU.T
Temperature meas. range upper limit
°C
C
5:225_1 8
T.F
Temperature substitute value
°C
S
6:311_1 8
Tb
Temperature at base conditions
K
C
6:312
8
Md.T
Temperature mode
-
C
6:317
7
Typ.T
Temp. sensor type
-
C
5:223
8
SNT
Serial number of temperature sensor
-
C
5:222
8
Eq1T
Coefficient 1 of temperature equation
-
C
5:280
8
Eq2T
Coefficient 2 of temperature equation
-
C
5:281
8
Eq3T
Coefficient 3 of temperature equation
-
C
5:282
8
T1Adj
Adjustment value 1 for temperature
°C
C
5:260_1 8
T2Adj
Adjustment value 2 for temperature
°C
C
5:261_1 8
Prog
Accept temperature adjustment
-
C
5:259
2
T.Mes
Temperature measurement
°C
-
5:210_1 4
T.MP
Ø
Measurement period mean temperature
°C
-
15:160 16
T.Mon max Month's maximum temperature
°C
-
17:160 16
T.Mon min
Month's minimum temperature
°C
-
18:160 16
(Legends: see page 22)
T
Temperature
T
is the temperature which is used for computing the conversion factor (
→
3.5)
and hence the volume at base conditions (
→
3.1).
In disturbance-free operation the measurement
T.Mes
(see below) is used:
T
=
T.Mes
.
With a relevant disturbance (alarm), the substitute value
T.F
(see below) is used:
T
=
T.F
.
In addition, disturbance quantities are then counted (
→
3.1, 3.2) and the message
"T Alarm Lim." displayed (
→
page 45 ). Relevant disturbances are:
−
T.Mes
is located outside of the set alarm limits
TMin
and
TMax
(see below).
−
With a connected encoder (Md.I1 = 5,
→
3.10) no actual volume can be
measured for more than 20 seconds. Since the gas flow variation is not known
for the time period and therefore no gas quantities can be assig ned to the
measured values of pressure and temperature, the conversion occurs as
disturbance quantities with substitute values for pressure and temperature.
(
→
4.5)
Summary of Contents for 83 462 140
Page 117: ...Volume Conversion Device EK260 Elster GmbH 117 A 2 Approval for Ex Zone 1 ...
Page 118: ...Volume Conversion Device EK260 118 Elster GmbH ...
Page 119: ...Volume Conversion Device EK260 Elster GmbH 119 ...
Page 120: ...Volume Conversion Device EK260 120 Elster GmbH ...
Page 121: ...Volume Conversion Device EK260 Elster GmbH 121 ...