MC Connection Diagram
1
2
3
4
5
6
7
8
16
15
14
13
12
11
10
9
Normally Closed
User can change
Fuse
Relay
Relay
Open Close Stop
Master
Control
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
AC Supply
Motor 1
Motor 1
AC Supply
AC Supply
Motor
2
Motor 2
AC Supply
AC Supply
B
Battery -
Open
Limit
Common
Motor 1
Close
Limit
Motor 1
Open
Limit
Motor 2
Close
Limit
Motor 2
Push Button
Open
Close
Stop
Common
PED Access
Photo Beam
+
12 VDC
- 1
2 VDC
Output 1 C
Output 1 NO
Output 2 C
Output 2 NC
Output 2 NO
+
-
Power
Output
LED
AC Supply :
24/12 Volts AC
Model :
MC
Designed by
ELSEMA
IN AUSTRALIA
Normally Closed
User can change
AC Supply
DNS
Day and Night Sensor
ELSEMA
Normally
Open
User can change
Eclipse
operating
system
Powered By
Receiver
Program 2
Program 1
Antenna 1
Shield
Antenna 2
Output Rated
at 250mA
12 or 24 Volts
AC Supply
Built-in
Receiver
DNS Connection : On the top right corner of the control card is a connection for Day and Night
Sensor(DNS). This sensor is available from Elsema and is used to detect day and night. This feature can
be used to auto close the gate at night, turn on the courtesy light or lights on your gates during the night
and many more features which require a day and night detection.
8
Double Gate & Door Controller
with Eclipse
®
Operating System (EOS)