Menu 11 – Motor Speed, Slow Speed Area
and Reverse Time
Menu No.
Motor Speed, Slow Speed
Area and Reverse Time
Factory
Default
Adjustable
11.1
Open Speed
80%
50% to 125%
11.2
Close Speed
70%
50% to 125%
11.3
Open and Close Slow Speed
50%
35% to 65%
11.4
Open Slow Speed Area
4
1 to 12
11.5
Close Slow Speed Area
5
1 to 12
11.6
Stop Reverse Delay
0.4 seconds
0.2 to 2.5 seconds
11.7
Exit
11.1 & 11.2 Open and Close Speed
This sets the speed at which the gates/doors will travel. If the gate/door is travelling too fast reduce this
value.
11.3 Slow Speed
This sets the speed at which the gates/doors will travel in the slow speed region. If the gates/doors is
travelling too slow increase this value.
11.4 & 11.5 Slow Speed Area
This sets the slow speed travel area. If you want more travel time for the slow speed area increase this
value.
11.6 Obstruction Stop Reverse Delay Time
This sets the stop and reverse delay time when the gates/doors hits an obstruction.
26
Double Gate & Door Controller
with Eclipse
®
Operating System (EOS)