Menu 15 – Operational Records
This is for information only.
Menu No.
Operational Records
15.1
Event History, up to 100 events are recorded in the memory
15.2
Displays Gates/Doors Operations and Currents Levels
15.3
Reset Maximum Current Records
15.4
Exit
15.1 Event History
The event history will store 100 events. The following events are recorded into the memory: Power
On, Low Battery, All input activations, Successful opening, Successful closing, Obstruction Detected,
Unsuccessful i-Learning Attempt, Factory Reset, DC Output Overloaded, AC Supply Failed, AC Supply
Restored, Autoclose, Security Close and Fuse Protect Obstruction.
15.2 Displays Gates/Doors Operations and Current Levels
This displays the number of open cycles, close cycles, pedestrian cycles, open obstructions, close
obstructions and both motor current levels. All maximum current values can be reset by the user from
Menu 15.3
Menu 14 – Password
This will allow the user to enter a password to prevent unauthorised users from entering the control card
settings. User must remember the password. The only way to reset a lost password is to send the control
card back to Elsema.
To delete a password select Menu 14.2 and press Master Control.
Menu 13 – i-Learning
This feature allows you to do the intelligent travel learning of the gates/doors. Follow the messages on
the LCD to complete the learning
28
Double Gate & Door Controller
with Eclipse
®
Operating System (EOS)