Instruction manual
I ELOshield
Rev. 20
09.03.2020
Page 35 of 85
Assigning the X2, 6 x 0.34 wire
Signal desig-
nation
Wire color
Technical data
Comments
DOUT1 NO
Green
Relay 1
Normally open contact
Connected with the breach of
the inner (red) zone in the
default configuration
DOUT1 NC
Brown
Relay 1
Normally closed contact
Connected with the breach of
the inner (red) zone in the
default configuration
DOUT1 CM
Yellow
Relay 1
Switching contact
Connected with the breach of
the inner (red) zone in the
default configuration
DOUT1 NO
Pink
Relay 2
Normally open contact
Connected with the breach of
the outer (yellow) zone in the
default configuration
DOUT1 NC
Gray
Relay 2
Normally closed contact
Connected with the breach of
the outer (yellow) zone in the
default configuration
DOUT1 CM
White
Relay 2
Switching contact
Connected with the breach of
the outer (yellow) zone in the
default configuration
Table 3.Identification of wires in X2 group
6.6.2
Example connections in X1 group
Example 1:
ELOshield is permanently activated.
Pink and red wire are connected to the power supply voltage of +12 VDC … +48 VDC
Blue and gray wires are connected to the ground
Example 2:
ELOshield is permanently activated (option two).
Red wire is connected to the power supply voltage of +12 VDC … +48 VDC
Blue wire is connected to the ground
Pink and gray wires are not connected (or connected to the ground)
The input 1 logic is configured as "normal" in the software.