IntelliTouch PC-Bus Controller (E281-4035)
Verify the controller’s switch settings are as follows:
12-Bit Mode
SW1 - ON
Reserved
SW2 - ON
Stream Mode
SW3 - OFF
Reserved
SW4 - ON
Z-axis enable
SW5 - ON
Reserved
SW6 - ON
Next, set the controller’s Base I/O Port address with the W2 and W3 jumpers. W3
selects the high-order address, and W2 th low-order address. The values of the
settings are shown in the following table:
W3
W2
HI (100X)
LOW (10X)
Position
Value
Position
Value
(from top)
(in hex)
(from top)
(in hex)
0
000
0
00
1
100
2
20
2 (recommended)
200
4
40
3
300
6
60
8 (recommended)
80
A
A0
C
C0
E
E0
To calculate the Base I/O Port address, add the values of the jumpered positions of
W3 and W2. For example, the E281-4035 is shipped jumpered for a Base I/O Port
address of 280 hexadecimal. W3 is jumpered in the third position (200), and W2 is
jumpered in the fifth position (80). The address is the sum of 200 + 80, which is
280.