56
elna 9900
C
C-1
Adjusting the Carriage Home Position (2)
[When the needle drop position C-1 is not centered
although the needle drop position C is centered.]
1 Loosen setscrews A.
Remove the X-carriag sensor plate.
2 Loosen the hexagonal socket screws B.
3 Move the carriage to the right with your hand.
Loosen the hexagonal socket C.
4 Adjust the position by moving the connecting
plate to the direction of arrow.
5 Tighten the hexagonal socket screw C.
6 Tighten hexagonal socket screws B.
* Confirm the adjustment of carriage position
sensor (1)
Carriag sensor plate
Hexagonal socket screws B
Setscrews A
Connecting plate
Hexagonal socket screws C